.. csv-table:: :header: "Command (GPIO/Value)", "Extra information" :widths: 20, 30 " ``ResetPulseCounter`` legacy method: ``ResetPulseCounter,`` "," Reset the counters (pulse counter and total counter) of P003 Pulse Counter. When using multiple instances of Pulse Counter tasks, use a prefix to address the right one. E.g. ``2.ResetPulseCounter``, ``[GasZaehler].ResetPulseCounter`` or ``GasZaehler.ResetPulseCounter`` to address task number 2 or the task with the name ``GasZaehler``. When task is neither identified as prefix nor as parameter, the first active Pulse Counter task will be affected. The command will also trigger a call to ``PLUGIN_READ`` as if it processes a normal successful read. " " ``SetPulseCounterTotal,value`` legacy method: ``SetPulseCounterTotal,value,`` "," Set the value of the total count of P003 Pulse Counter. When using multiple instances of Pulse Counter tasks, use a prefix to address the right one. E.g. ``2.SetPulseCounter,1000``, ``[GasZaehler].SetPulseCounter,1000`` or ``GasZaehler.SetPulseCounter,1000`` to address task number 2 or the task with the name ``GasZaehler``. When task is neither identified as prefix nor as parameter, the first active Pulse Counter task will be affected. A call to set the counter total will also trigger a call to ``PLUGIN_READ`` as if it processes a normal successful read. N.B. The set value is the internal value, so any present formula will be processed after this value is set. " " ``LogPulseStatistic,`` Optional subcommands: * ``r`` reset error and overdue counters. * ``i`` temporary increases the log level for regular statisticel log entries from ``Debug`` to ``Info`` "," Initiate a single log entry with statistical information of current PULSE counter parameters (only if PULSE mode type is being used. Cf. special chapter about ``Statistical logging`` in P003 plugin documentation). The is executed AFTER writing to logfile, so you see the result of the reset in consecutive loggings. The ``i`` subcommand allows you to increase the log level to ``Info`` and still see the Pulse Counter's statistical logings without other not needed ``Debug`` messages. This setting is valid until next reset. When using multiple instances of Pulse Counter tasks, use a prefix to address the right one. E.g. ``2.LogPulseStatistic,i``, ``[GasZaehler].LogPulseStatistic,i`` or ``GasZaehler.LogPulseStatistic,i`` to address task number 2 or the task with the name ``GasZaehler``. When the task-prefix is omitted, the first active Pulse Counter task will be affected. N.B. Note that this single log entry is done, when Log Level is set to ``Info``. Only the regular statistical logging is done by default on level ``Debug``, but can be temporary increased to ``Info`` with the above ``i`` command. "