.. csv-table:: :header: "Command Syntax", "Extra information" :widths: 20, 30 " | Commands to control the AXP192 output voltages and GPIO pins. "," | **Attention**: Commands will fail if the selected output is 'N/C - Unused' according to the selected Predefined device configuration. " " | ``axp,ldo2,`` | ``voltage`` range: 0..3300 mV. "," | Set output ``LDO2`` to the specified voltage. When set below 1800 mV the output will be turned off. " " | ``axp,ldo3,`` | ``voltage`` range: 0..3300 mV. "," | Set output ``LDO3`` to the specified voltage. When set below 1800 mV the output will be turned off. " " | ``axp,ldoio,`` | ``voltage`` range: 1800..3300 mV. "," | Set AXP192 output for ``LDOIO``, setting the level for all ``GPIO`` pins of AXP192, to the specified voltage. When set below 1800 mV the command will fail. " " | ``axp,ldo2perc,`` | ``percentage`` range: 1..100 %. "," | Set output ``LDO2`` to the specified percentage within the mapping specified. The default mapping is the range from 1800..3300 mV, so 1% maps to 1800 mV and 100% to 3300mV. When set to 0 % the output will be turned off. | See: ``ldo2map`` sub-command below. " " | ``axp,ldo3perc,`` | ``percentage`` range: 1..100 %. "," | Set output ``LDO3`` to the specified percentage within the mapping specified. The default mapping is the range from 1800..3300 mV, so 1% maps to 1800 mV and 100% to 3300mV. When set to 0 % the output will be turned off. | See: ``ldo3map`` sub-command below. " " | ``axp,ldoioperc,`` | ``percentage`` range: 1..100 %. "," | Set AXP192 ``LDOIO`` outputs to the specified percentage within the mapping specified. The default mapping is the range from 1800..3300 mV, so 1% maps to 1800 mV and 100% to 3300mV. When set to 0 % the command will fail. | See: ``ldoiomap`` sub-command below. " " | ``axp,dcdc2perc,`` | ``percentage`` range: 1..100 %. "," | Set output ``DCDC2`` to the specified percentage within the mapping specified. The default mapping is the range from 700..2750 mV, so 1% maps to 700 mV and 100% to 2750mV. When set to 0 % the output will be turned off. | See: ``dcdc2map`` sub-command below. " " | ``axp,dcdc3perc,`` | ``percentage`` range: 1..100 %. "," | Set output ``DCDC3`` to the specified percentage within the mapping specified. The default mapping is the range from 700..3500 mV, so 1% maps to 700 mV and 100% to 3500mV. When set to 0 % the output will be turned off. | See: ``dcdc3map`` sub-command below. " " | ``axp,ldo2map,,`` | ``lowvoltage``, ``highvoltage`` range: 0..3300 mV. | ``lowvoltage`` must be lower than ``highvoltage``. "," | Set the mapping range for ``ldo2perc`` sub-command to the specified voltage range. " " | ``axp,ldo3map,,`` | ``lowvoltage``, ``highvoltage`` range: 0..3300 mV. | ``lowvoltage`` must be lower than ``highvoltage``. "," | Set the mapping range for ``ldo3perc`` sub-command to the specified voltage range. " " | ``axp,ldoiomap,,`` | ``lowvoltage``, ``highvoltage`` range: 1800..3300 mV. | ``lowvoltage`` must be lower than ``highvoltage``. "," | Set the mapping range for ``ldoioperc`` sub-command to the specified voltage range. " " | ``axp,dcdc2map,,`` | ``lowvoltage``, ``highvoltage`` range: 0..2750 mV. | ``lowvoltage`` must be lower than ``highvoltage``. "," | Set the mapping range for ``dcdc2perc`` sub-command to the specified voltage range. " " | ``axp,dcdc3map,,`` | ``lowvoltage``, ``highvoltage`` range: 0..3500 mV. | ``lowvoltage`` must be lower than ``highvoltage``. "," | Set the mapping range for ``dcdc3perc`` sub-command to the specified voltage range. " " | ``axp,gpio0,`` | ``state``: 0 (off/low) or 1 (on/high) "," | Set the AXP192 ``GPIO0`` pin state. " " | ``axp,gpio1,`` | ``state``: 0 (off/low) or 1 (on/high) "," | Set the AXP192 ``GPIO1`` pin state. " " | ``axp,gpio2,`` | ``state``: 0 (off/low) or 1 (on/high) "," | Set the AXP192 ``GPIO2`` pin state. " " | ``axp,gpio3,`` | ``state``: 0 (off/low) or 1 (on/high) "," | Set the AXP192 ``GPIO3`` pin state. " " | ``axp,gpio4,`` | ``state``: 0 (off/low) or 1 (on/high) "," | Set the AXP192 ``GPIO4`` pin state. "