.. csv-table:: :header: "Command Syntax", "Extra information" :widths: 20, 30 " | Commands to control the AXP2101 port voltages & states. "," | **Attention**: Commands will fail if the selected port is 'Protected' or 'Disabled' according to the selected Predefined device configuration. " " | ``axp,readchip`` "," | List the current values as configured in the chip. The logging level must be set to ``INFO``. This data can be used to configure additional predefined devices. " " | ``axp,voltage,,`` | ``port`` one of the available ports. | ``voltage`` range: 0.. mV. "," | Set selected port to the specified voltage. When set to 0 mV the port will be turned off. | Ports of the AXP2101: ``DCDC1`` .. ``DCDC4``, ``ALDO1`` .. ``ALDO4``, ``BLDO1``, ``BLDO2``, ``DLDO1``, ``DLDO2`` or ``CPULDOS``. | The max port voltage depends on the selected port, and is available in the technical documentation of the AXP2101. " " | ``axp,on,`` | ``port`` one of the available ports. "," | Set the selected AXP2101 port ON. | Ports of the AXP2101: ``DCDC1`` .. ``DCDC4``, ``ALDO1`` .. ``ALDO4``, ``BLDO1``, ``BLDO2``, ``DLDO1``, ``DLDO2`` or ``CPULDOS``. " " | ``axp,off,`` | ``port`` one of the available ports. "," | Set the selected AXP2101 port OFF. | Ports of the AXP2101: ``DCDC1`` .. ``DCDC4``, ``ALDO1`` .. ``ALDO4``, ``BLDO1``, ``BLDO2``, ``DLDO1``, ``DLDO2`` or ``CPULDOS``. " " | ``axp,percentage,,`` | ``port`` one of the available Ports. | ``percentage``: 0 (off/low) or 1..100% "," | Set the selected port to Off for 0%, or On in range .. for 1..100%. | Ports of the AXP2101: ``DCDC1`` .. ``DCDC4``, ``ALDO1`` .. ``ALDO4``, ``BLDO1``, ``BLDO2``, ``DLDO1``, ``DLDO2`` or ``CPULDOS``. | The min and max port voltages depend on the selected port, and are available in the technical documentation of the AXP2101. "