.. include:: ../Plugin/_plugin_substitutions_p06x.repl
|
|
.. _P067_page:
|
|
|
|
|P067_typename|
|
|
==================================================
|
|
|
|
|P067_shortinfo|
|
|
|
|
Plugin details
|
|
--------------
|
|
|
|
Type: |P067_type|
|
|
|
|
Name: |P067_name|
|
|
|
|
Status: |P067_status|
|
|
|
|
GitHub: |P067_github|_
|
|
|
|
Maintainer: |P067_maintainer|
|
|
|
|
Used libraries: |P067_usedlibraries|
|
|
|
|
Supported hardware
|
|
------------------
|
|
|
|
|P067_usedby|
|
|
|
|
There are several ways to connect load cells to the HX711 board, depending on the number of load cells used.
|
|
|
|
1 load cell connected:
|
|
|
|
.. image:: P067_1LoadCellHardware.png
|
|
|
|
2 load cells connected:
|
|
|
|
.. image:: P067_2LoadCellHardware.png
|
|
|
|
4 load cells connected:
|
|
|
|
.. image:: P067_4LoadCellHardware.png
|
|
|
|
Separate A and B channels
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
When connecting 2 (sets of) load cells on both A and B channels, to get independent measurements, start with the 1, 2 or 4 load cell setup, above, then connect the ``E+`` and ``E-`` wires of the second load cell (set) in parallel with the first load cell, the ``A-`` wire of the second load cell to ``B-`` input and the ``A+`` wire to the ``B+`` input of the board.
|
|
|
|
Description
|
|
-----------
|
|
|
|
The HX711 load-cell signal amplifier can be used for creating a scale, or to detect if the weight of an object changes. There can be 1, 2 or 4 load cells connected to each channel, in specific configurations as shown above.
|
|
|
|
Configuration
|
|
--------------
|
|
|
|
.. image:: P067_DeviceConfiguration.png
|
|
|
|
**Name** A unique name should be entered here.
|
|
|
|
**Enabled** The device can be disabled or enabled. When not enabled the device should not use any resources.
|
|
|
|
Sensor
|
|
^^^^^^
|
|
|
|
**GPIO -> SCK**: The GPIO pin that is connected to the clock input of the board.
|
|
|
|
**GPIO <- DT**: The GPIO pin that is connected to the Data output of the board.
|
|
|
|
Device Settings
|
|
^^^^^^^^^^^^^^^^
|
|
|
|
Measurement channel A
|
|
"""""""""""""""""""""
|
|
|
|
**Oversampling**: When enabled, the reported values are averaged during the set **Interval** to stabilize the, often somewhat fluctuating, returned values.
|
|
|
|
**Mode**: Channel A offers 3 modes of operation:
|
|
|
|
.. image:: P067_ModeAOptions.png
|
|
|
|
*Off*: The channel is disabled.
|
|
|
|
*Gain 64*: Enabled, signal enhancement with gain factor 64 is applied.
|
|
|
|
*Gain 128*: Enabled, signal enhancement with gain factor 128 is applied.
|
|
|
|
**Offset**: The offset is subtracted from the returned result. As each load cell has its own characteristic, this can be used to get a calibrated result value. The **Tare** checkbox (always off, unless checked by the user) can be used to fetch and set the last measured value as the offset.
|
|
|
|
Measurement channel B
|
|
"""""""""""""""""""""
|
|
|
|
The HX711 board offers a second input, often labelled B, where another load cell can be connected. To get the values of that channel, this part of the configuration has to be used.
|
|
|
|
**Oversampling**: When enabled, the reported values are averaged during the set **Interval** to stabilize the, often somewhat fluctuating, returned values. A new measurement sample is taken every 60 msec. (3 alternating measurements for the 3 gain options, 1 every 20 msec.) Max. 250 samples are used for oversampling.
|
|
|
|
**Mode**: Channel B offers 2 modes of operation:
|
|
|
|
.. image:: P067_ModeBOptions.png
|
|
|
|
*Off*: The channel is disabled.
|
|
|
|
*Gain 32*: Enabled, signal enhancement with gain factor 32 is applied.
|
|
|
|
**Offset**: The offset is subtracted from the returned result. As each load cell has its own characteristic, this can be used to get a calibrated result value. The **Tare** checkbox (always off, unless checked by the user) can be used to fetch and set the last measured value as the offset.
|
|
|
|
.. note::
|
|
The somewhat irregular Gain settings per channel as shown are a limitation in the HX711 hardware, *not* in the plugin or ESPEasy software.
|
|
|
|
Two Point Calibration Channel A
|
|
"""""""""""""""""""""""""""""""
|
|
|
|
**Calibration Enabled**: Checked when 2-point calibration should be applied.
|
|
|
|
**Point 1**: The raw value, mapped to the desired output value.
|
|
|
|
**Point 2**: The raw value, mapped to the desired output value.
|
|
|
|
Two Point Calibration Channel B
|
|
"""""""""""""""""""""""""""""""
|
|
|
|
**Calibration Enabled**: Checked when 2-point calibration should be applied.
|
|
|
|
**Point 1**: The raw value, mapped to the desired output value.
|
|
|
|
**Point 2**: The raw value, mapped to the desired output value.
|
|
|
|
Calibration procedure
|
|
^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
To calibrate your measurements to a defined range, f.e. ``kg`` or ``g``, this procedure can be used:
|
|
|
|
* Make sure no load is on the load cell, the plugin is enabled, and some measurements have been registered (wait for the **Interval** time to have passed at least a few times, and non-zero values are shown in the device overview page).
|
|
|
|
* Check the **Calibration Enabled** checkbox.
|
|
|
|
* Reset the **Point 1** and **Point 2** values to 0 and 0.
|
|
|
|
* Set the offset to the current measurement, by checking the **Tare** checkbox, and Submit the settings.
|
|
|
|
* Place a reference-load of known value on the load cell that is near the highest range of measurement to be expected, f.e. 25 kg of weight on a 50 kg load cell if the regular measurement should be around 25 kg.
|
|
|
|
* Take note of the measured value, either from the Devices overview page or the log, available via the serial interface or the Tools/Log page.
|
|
|
|
* Set the **Point 2** values to that measured value and the actual weight that was used, f.e. 25000 (g) or 25 (kg). When calibrating to ``g`` the value can still be shown in ``kg`` by applying the formula ``%value%/1000``, optionally setting the number of decimals to 3 to show full resolution.
|
|
|
|
* Submit the page to store the calibration.
|
|
|
|
.. note::
|
|
Disclaimer: As the load versus output signal for a load cell isn't guaranteed to be linear, calibration using the minimum and maximum expected load for calibration will result in a best effort output.
|
|
|
|
Data Acquisition
|
|
----------------
|
|
|
|
The Data Acquisition, Send to Controller and Interval settings are standard available configuration items. Send to Controller is only visible when one or more Controllers are configured.
|
|
|
|
* **Interval** By default, Interval will be set to 60 sec. The minimum value allowed is 1 sec.
|
|
|
|
Values
|
|
^^^^^^
|
|
|
|
There are 2 values available for this sensor, named ``WeightChanA`` and ``WeightChanB``. A formula can be set to recalculate, f.e. to apply a division, or multiplication, using ``%value%/1000``. The number of decimals is by default set to 2.
|
|
|
|
Depending on the build-options used, a ``Stats`` checkbox per Value is available, and when checked, statistics for the value are stored in memory, and a graph can be shown in the Device configuration page. These statistics can be queried, similar like documented in the :ref:`p002_page` plugin page.
|
|
|
|
Commands available
|
|
^^^^^^^^^^^^^^^^^^
|
|
|
|
.. include:: P067_commands.repl
|
|
|
|
.. Events
|
|
.. ~~~~~~
|
|
|
|
.. .. include:: P067_events.repl
|
|
|
|
Change log
|
|
----------
|
|
|
|
.. versionchanged:: 2.0
|
|
...
|
|
|
|
|added| 2023-01-01: Allow multiple instances of the plugin to be active, Channel B now returns a reliable result.
|
|
|
|
|added|
|
|
Major overhaul for 2.0 release.
|
|
|
|
.. versionadded:: 1.0
|
|
...
|
|
|
|
|added|
|
|
Initial release version.
|
|
|
|
|
|
|
|
|
|
|