.. include:: ../Plugin/_plugin_substitutions_p03x.repl
|
|
.. _P030_BMP280_page:
|
|
|
|
BMP280
|
|
======
|
|
|
|
|P030_typename|
|
|
|P030_status|
|
|
|
|
.. image:: P030_BMP280_1.jpg
|
|
|
|
Introduction
|
|
------------
|
|
|
|
|
|
Specifications:
|
|
* Temperature (-40C to +85C)
|
|
* Barometric pressure (300-1100 hPa)
|
|
|
|
.. warning:: The BMP280 is easily mistaken for its big brother the BM**E**280. The :ref:`P028_page` can also be used
|
|
to control the BMP280.
|
|
|
|
Wiring
|
|
------
|
|
|
|
.. code-block:: html
|
|
|
|
ESP BMP280
|
|
GPIO (4) <--> SDI (SDA)
|
|
GPIO (5) <--> SCK (SCL)
|
|
|
|
Power
|
|
3.3V <--> VIN
|
|
GND <--> GND
|
|
|
|
.. note:: If you have change the I2C settings in the hardware setup you need to connect to those instead of GPIO 4 and 5.
|
|
|
|
.. note:: Only use 3.3V BMP280 boards. The ESP pins are not 5V tolerant. Depending on the make of the BMP280 board,
|
|
pull-up resistors on SDA and SDC may be absent. 4k7 types are fine. When more I2C devices are being used, only one set
|
|
of pull-up resistors is required or even allowed. It may be necessary to add a ceramic 100nF capacitor across the power
|
|
lines, close to the BMP280 board.
|
|
|
|
Setup
|
|
-----
|
|
|
|
.. image:: P030_Setup_BMP280_1.png
|
|
|
|
Task settings
|
|
~~~~~~~~~~~~~
|
|
|
|
* **Device**: Name of plugin
|
|
* **Name**: Name of the task (example name **BMP**)
|
|
* **Enable**: Should the task be enabled or not
|
|
|
|
Sensor
|
|
^^^^^^
|
|
|
|
* **i2C address**: You can use two BMP280 at the same time, choose address here. If you only use one, stay with the default address.
|
|
* **Altitude**: Set the level above sea for your unit. This is done in order to get a correct pressure value.
|
|
|
|
Data acquisition
|
|
^^^^^^^^^^^^^^^^
|
|
|
|
* **Send to controller** 1..3: Check which controller (if any) you want to publish to. All or no controller can be used.
|
|
* **Interval**: How often should the task publish its value (5..15 seconds is normal).
|
|
|
|
Indicators (recommended settings)
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
.. csv-table::
|
|
:header: "Indicator", "Value Name", "Interval", "Decimals", "Extra information"
|
|
:widths: 8, 5, 5, 5, 40
|
|
|
|
"Temperature", "Celsius", "10", "1", ""
|
|
"Pressure", "hPa", "10", "0", ""
|
|
|
|
Rules examples
|
|
--------------
|
|
|
|
.. code-block:: html
|
|
|
|
on BMP#hPa do
|
|
if BMP#hPa>999
|
|
Publish,%sysname%/pressure,Is normal
|
|
endif
|
|
endon
|
|
|
|
.. Commands available
|
|
.. ~~~~~~~~~~~~~~~~~~
|
|
|
|
.. .. include:: P030_commands.repl
|
|
|
|
Where to buy
|
|
------------
|
|
|
|
.. csv-table::
|
|
:header: "Store", "Link"
|
|
:widths: 5, 40
|
|
|
|
"AliExpress","`Link 1 ($) <http://s.click.aliexpress.com/e/qMVQ66k>`_"
|
|
"Banggood","`Link 2 ($) <https://www.banggood.com/search/bmp280.html?sbc=1&p=V3270422659778201806&custlinkid=99988>`_"
|
|
"eBay","`Link 3 ($) <http://rover.ebay.com/rover/1/711-53200-19255-0/1?ff3=4&pub=5575404073&toolid=10001&campid=5338336929&customid=&mpre=https%3A%2F%2Fwww.ebay.com%2Fsch%2Fi.html%3F_from%3DR40%26_trksid%3Dm570.l1313%26_nkw%3Dbmp280%26_sacat%3D0>`_"
|
|
|
|
|affiliate|
|
|
|
|
|
|
.. More pictures
|
|
.. -------------
|
|
|
|
.. .. image:: P030_BMP280_2.jpg
|