.. csv-table::
:header: "Event", "Example"
:widths: 30, 20
"
``<taskname>#<valuename>``
As described already, each task can produced one or more events, one for each measured value. You should not name your devices and value names so that the combination equals to any of the below listed system events!
","
.. code-block:: none
on DHT11Outside#Temperature>20 do
GPIO,2,1
endon
"
"
``System#Wake``
Triggered after power on.
","
.. code-block:: none
on System#Wake do
GPIO,15,1
endon
"
"
``System#Boot``
Triggered at boot time.
","
.. code-block:: none
on System#Boot do
GPIO,2,1
timerSet,1,30
endon
"
"
``System#Sleep``
Triggered just before the ESP goes to deep sleep.
","
.. code-block:: none
on System#Sleep do
GPIO,2,0
endon
"
"
``MQTT#Connected``
Triggered when the ESP has connected to broker.
","
.. code-block:: none
on MQTT#Connected do
Publish,%sysname%/status,First message!
endon
"
"
``MQTT#Disconnected``
Triggered when the ESP has disconnected from the broker.
","
.. code-block:: none
on MQTT#Disconnected do
Reboot
endon
"
"
``MQTTimport#Connected``
Triggered when the ESP has connected to broker (the MQTT Import plugin uses a separate connection than the generic one).
","
.. code-block:: none
on MQTTimport#Connected do
Publish,%sysname%/status,MQTT Import is now operational
endon
"
"
``MQTTimport#Disconnected``
Triggered when the ESP has disconnected from the broker (the MQTT Import plugin uses a separate connection than the generic one).
","
.. code-block:: none
on MQTTimport#Disconnected do
Reboot
endon
"
"
``WiFi#Connected``
Triggered when the ESP has connected to Wi-Fi.
","
.. code-block:: none
on WiFi#Connected do
SendToHTTP,url.com,80,/report.php?hash=123abc456&t=[temp2#out]
endon
"
"
``WiFi#ChangedAccesspoint``
Triggered when the ESP has changed to access point, will also trigger first time the unit connects to the Wi-Fi.
","
.. code-block:: none
on WiFi#ChangedAccesspoint do
Publish,%sysname%/status,AP changed
endon
"
"
``WiFi#ChangedWiFichannel``
Triggered when the ESP is connected to the AP on a different channel, will also trigger first time the unit connects to the Wi-Fi.
This has been added in build mega-20190910
","
.. code-block:: none
on WiFi#ChangedWiFichannel do
Publish,%sysname%/status,channel changed
endon
"
"
``WiFi#APmodeEnabled``
Triggered when the ESP has set the AP mode (access point) active.
This may happen when no valid WiFi settings are found or the ESP cannot connect to the set AP, but it can also be enabled via some command.
N.B. Sending a publish command may not be very useful on this event, since this will mainly happen when there is no WiFi connection.
","
.. code-block:: none
on WiFi#APmodeEnabled do
... // Some command
endon
"
"
``WiFi#APmodeDisabled``
Triggered when the ESP has disabled the AP mode (access point).
This can happen some time (default 60 seconds) after a WiFi connection has been made. Or disabled using some command.
","
.. code-block:: none
on WiFi#APmodeDisabled do
Publish,%sysname%/status,AP disabled
endon
"
"
``Login#Failed``
Triggered when (someone) has tried to login to a ESP unit with admin password enabled, but have failed to enter correct password.
","
.. code-block:: none
on Login#Failed do
Publish,%sysname%/warning,Intruder alert!
endon
"
"
``Time#Initialized``
Triggered the first time (after boot) NTP is updating the unit.
","
.. code-block:: none
on Time#Initialized do
Publish,%sysname%/Time,%systime%
endon
"
"
``Time#Set``
Triggered when the time is set by an update from NTP.
","
.. code-block:: none
on Time#Set do
Publish,%sysname%/Time,%systime%
Publish,%sysname%/NTP,Updated time at: %systime%
endon
"
"
``Rules#Timer=``
As described already, triggered when a rules timer ends (setting a timer to 0 will disable the timer).
","
.. code-block:: none
on Rules#Timer=1 do
GPIO,2,1
endon
"
"
``Clock#Time=``
Triggered every minute with day and time like: Mon,12:30 or Tue,14:45. You can define triggers on specific days or all days using 'All' for days indicator. You can also use wildcards in the time setting like All,**:00 to run every hour.
","
.. code-block:: none
on Clock#Time=All,12:00 do //will run once a day at noon
GPIO,2,1
endon
on Clock#Time=All,**:30 do //will run half past every hour
GPIO,2,1
endon
on Clock#Time=All,%sunrise% do //will run at sunrise (%sunset% is also available)
GPIO,2,1
endon
"
"
``GPIO#N``
If the command 'Monitor' is used to monitor a given pin you will receive an event for that GPIO as soon as it's state changes. As seen in the example you can always use the square brackets together with the task/value name of ``Plugin#GPIO#Pinstate#N`` to get the state, but to trigger events you need to add the monitor command (preferably at boot).
","
.. code-block:: none
on System#Boot do
Monitor GPIO,15
endon
on GPIO#15=0 do
if [Plugin#GPIO#Pinstate#13]=0
// do something
endif
endon
on GPIO#15=1 do
if [Plugin#GPIO#Pinstate#13]=1
// do something
endif
endon
"