.. _P003_LJ12A3_page:
|
|
|
|
LJ12A3
|
|
======
|
|
|
|
|P003_typename|
|
|
|P003_status|
|
|
|
|
.. image:: P003_LJ12A3_1.jpg
|
|
|
|
Introduction
|
|
------------
|
|
The ESP8266 module can be used as a general purpose digital pulse counter device for various digital sensors.
|
|
Think about optical sensors with a digital output. To be used for things like gas, water, electricity, door open/close counters, etc.
|
|
|
|
In this example we will connect an inductive proximity switch (LJ12A3-4-Z/BX).
|
|
A LJ12A3-4-Z/BX module can be used in order to detect metal.
|
|
For example in your water consumption meter (as seen in picture).
|
|
|
|
Specifications:
|
|
* Inductive proximity sensor
|
|
* Detection distance: 4mm
|
|
* Working voltage range: 10V-30V
|
|
* Dimension: M12x10x55mm
|
|
|
|
|
|
Wiring
|
|
------
|
|
|
|
.. code-block:: none
|
|
|
|
ESP LJ12A3
|
|
GPIO (14) <--> Signal (black)
|
|
|
|
Power
|
|
12V <--> VCC (brown)
|
|
GND <--> GND (blue)
|
|
|
|
.. note:: You need to use a voltage divider to get the signal level down from 12V to 5V.
|
|
|
|
|
|
The LJ12A3-4-Z/BX-**5V** way
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
Just buy the 5V version of the proximity sensor and you are good to go.
|
|
|
|
The resistor way
|
|
^^^^^^^^^^^^^^^^
|
|
|
|
.. image:: P003_LJ12A3_2.png
|
|
|
|
The 7805 way
|
|
^^^^^^^^^^^^
|
|
|
|
7805 IC specifications:
|
|
* Input voltage range 7-35V
|
|
* Current rating Ic = 1A
|
|
* Output voltage range: Vmax=5.2V, Vmin=4.8V
|
|
* Where to buy: `AliExpress ($) <http://s.click.aliexpress.com/e/bmR1wUxq>`_
|
|
|
|
.. image:: P003_LJ12A3_3.png
|
|
|
|
.. note:: 7805 is not very efficient and has drop-out voltage problems. A lot of energy is wasted in the form of heat.
|
|
Higher the input voltage, less efficient your 7805 will be.
|
|
|
|
Setup
|
|
-----
|
|
|
|
.. image:: P003_Setup_LJ12A3_1.png
|
|
|
|
.. danger:: Only task number 1..4 is currently supported for the pulse plugin!
|
|
|
|
Task settings
|
|
^^^^^^^^^^^^^
|
|
|
|
* **Device**: Name of plugin
|
|
* **Name**: Name of the task (example name **WaterMeter**)
|
|
* **Enable**: Should the task be enabled or not
|
|
|
|
Sensor
|
|
^^^^^^
|
|
|
|
* **GPIO <-- Pulse**: Pulse input is generally set to **GPIO 14 (D5)**.
|
|
* **Debounce time**: Debounce time is generally set to **100**.
|
|
* **Counter type**: In this example the type is set to **Delta/Total/Time**.
|
|
* **Mode type**: Pulse input is generally set to **Falling**
|
|
|
|
``LOW`` = count when signal go from not low to low (0.8+V to 0.8-V)
|
|
|
|
``CHANGE`` = count on signal being changed, low to high (0.8-V to 2.4+V) or high to low (2.4+V to 0.8-V)
|
|
|
|
``RISING`` = count if signal is rising, from low to not low (0.8-V to 0.8+V)
|
|
|
|
``FALLING`` = count if signal is falling, from high to not high (2.4+V to 2.4-V)
|
|
|
|
.. warning:: GPIO 16 (D0) is not compatible with pulse counters.
|
|
|
|
Data acquisition
|
|
^^^^^^^^^^^^^^^^
|
|
|
|
* **Send to controller** 1..3: Check which controller (if any) you want to publish to. All or no controller can be used.
|
|
* **Interval**: How often should the task publish its value (5..15 seconds is normal).
|
|
|
|
|
|
Indicators (recommended settings)
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
.. csv-table::
|
|
:header: "Indicator", "Value Name", "Interval", "Decimals", "Extra information"
|
|
:widths: 8, 5, 5, 5, 40
|
|
|
|
"Count", "mL", "5", "2", "Using the formula ``%value%*20*0.1`` to convert the pulse count into liters per minute.
|
|
You might have to tweak the value to fit your application, our flow meter gives 0.1L per pulse and since
|
|
our interval was set to 5 seconds we have to multiply the value with ``20`` (the reading is done once every
|
|
20th of a minute) and also multiply it with ``0.1`` because that is the value in liters (per pulse).
|
|
"
|
|
"Total", "Total", "N/A", "1", "Total value is the counted pulses since last reboot.
|
|
.. note:: Only updated if counter type is set to ``Delta/Total/Time``, ``Total``, or ``Delta/Total``
|
|
"
|
|
"Time", "Time", "N/A", "0", "Time since last pulse was intercepted, in mSec.
|
|
.. note:: Only updated if counter type is set to ``Delta/Total/Time``
|
|
"
|
|
|
|
Rules examples
|
|
--------------
|
|
|
|
.. code-block:: none
|
|
|
|
On WaterMeter#mL Do
|
|
If [WaterMeter#mL]=0
|
|
Publish,%sysname%/WaterConsumption/status,No water running
|
|
Else
|
|
Publish,%sysname%/WaterConsumption/status,Water is being tapped
|
|
EndIf
|
|
EndOn
|
|
|
|
.. Commands available
|
|
.. ~~~~~~~~~~~~~~~~~~
|
|
|
|
.. .. include:: P003_commands.repl
|
|
|
|
Where to buy
|
|
------------
|
|
|
|
.. csv-table::
|
|
:header: "Store", "Link"
|
|
:widths: 5, 40
|
|
|
|
"AliExpress","`Link 1 ($) <http://s.click.aliexpress.com/e/1YcZUUo>`_ `Link 2 ($) <http://s.click.aliexpress.com/e/cWBJkHes>`_"
|
|
"Banggood","`Link 3 ($) <https://www.banggood.com/LJ12A3-4-ZBY-PNP-DC6-36V-Inductive-Proximity-Sensor-Detection-Switch-p-982679.html?p=V3270422659778201806>`_"
|
|
"eBay","`Link 4 ($) <https://rover.ebay.com/rover/1/711-53200-19255-0/1?icep_id=114&ipn=icep&toolid=20004&campid=5338336929&mpre=https%3A%2F%2Fwww.ebay.com%2Fsch%2Fi.html%3F_from%3DR40%26_trksid%3Dm570.l1313%26_nkw%3DLJ12A3%26_sacat%3D0%26LH_TitleDesc%3D0%26_osacat%3D0%26_odkw%3DAnalog%2BPressure%2Bsensor>`_"
|
|
|
|
|affiliate|
|
|
|
|
|
|
.. More pictures
|
|
.. -------------
|