tSense (K70)
|
|
============
|
|
|
|
|P052_typename|
|
|
|P052_status|
|
|
|
|
.. image:: P052_tSense_K70_1.jpg
|
|
|
|
Introduction
|
|
------------
|
|
|
|
Using the plugin P052 Senseair you can use the tSense (K70) as a sensor for temperature,
|
|
humidity and carbon dioxide. You can even use it to monitor the status of the internal relay,
|
|
or control the relay as well. If you have the EFA version of the tSense the temperature
|
|
adjustment is also possible to monitor.
|
|
|
|
The standard model of tSense display temperature, humidity and carbon dioxide level on the main page.
|
|
The relay can only be set to trigger by the settings menu where you can have a target level where the relay will activate.
|
|
|
|
.. note::
|
|
For both models the user password for the settings is by default "1111" and for the advanced settings level the password is "2001".
|
|
|
|
Specifications:
|
|
* 0 to 2000 ppm
|
|
* 12VDC, 24VAC/DC
|
|
* UART communication (Modbus (MB) or BACnet (BAC) protocol over RS485)
|
|
* 15 years life span
|
|
* No burn-in needed, will stabilize after 8 days at worst depending on placement environment
|
|
|
|
.. warning::
|
|
CONNECTING THIS PLUGIN WILL VOID THE WARRANTY OF YOUR tSENSE!
|
|
|
|
Wiring
|
|
------
|
|
|
|
.. code-block:: none
|
|
|
|
ESP tSense
|
|
GPIO (7) <--> TX (see pictures further down)
|
|
GPIO (8) <--> RX (see pictures further down)
|
|
|
|
Power
|
|
5.0V <--> VCC (see pictures further down)
|
|
GND <--> GND (see pictures further down)
|
|
|
|
Set up the K70 according to this simple schematics. If you want to take extra precautions you should add 47R
|
|
resistor or similar to the TX and RX signals (this is not used in the pictures below). In this example we
|
|
use the Wemos D1 mini and piggy back the power from the K70 5V via.
|
|
|
|
Setup
|
|
-----
|
|
|
|
.. image:: P052_Setup_tSense_K70_1.png
|
|
|
|
Task settings
|
|
~~~~~~~~~~~~~
|
|
|
|
* **Device**: Name of plugin
|
|
* **Name**: Name of the task (example name **CO2**)
|
|
* **Enable**: Should the task be enabled or not
|
|
|
|
Sensor
|
|
^^^^^^
|
|
|
|
* **GPIO <-- TX**: TX is generally set to **GPIO 13 (D7)**.
|
|
* **GPIO --> RX**: RX is generally set to **GPIO 15 (D8)**.
|
|
* **Sensor**: In this example we use the carbon dioxide sensor.
|
|
|
|
.. note:: TX GPIO 1 (D10) and RX GPIO 3 (D9) is hardware serial and have been reported to work better for some users over time compared to the
|
|
bit-banging (soft) serial used over GPIO 13 and 15.
|
|
|
|
Data acquisition
|
|
^^^^^^^^^^^^^^^^
|
|
|
|
* **Send to controller** 1..3: Check which controller (if any) you want to publish to. All or no controller can be used.
|
|
* **Interval**: How often should the task publish its value (5..15 seconds is normal).
|
|
|
|
Indicators (recommended settings)
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
.. csv-table::
|
|
:header: "Indicator", "Value Name", "Interval", "Decimals", "Extra information"
|
|
:widths: 8, 5, 5, 5, 40
|
|
|
|
"Error status", "Error", "15", "0", "
|
|
Used to present errors (if any):
|
|
|
|
``-1`` No error
|
|
|
|
``0`` No ability to communicate with CO2 sensor module.
|
|
|
|
``1`` CO2 measurement error.
|
|
|
|
``2`` Temp measurement error.
|
|
|
|
``3`` No ability to communicate with RH/T sensor module.
|
|
|
|
``4`` RH measurement error
|
|
|
|
``5`` Temp measurement error, sensor will use CO2 sensor temperature if RH/T temperature is unavailable. S_Temp will be set to NTC_Temp.
|
|
|
|
``6`` (not used)
|
|
|
|
``7`` (not used)
|
|
|
|
``8`` Error in output configuration. Output is still updated, i.e. can be 0-10V.
|
|
|
|
``9`` One or several bytes of sensors parameter memory (settings) are corrupt.
|
|
"
|
|
"Carbon dioxide", "ppm", "15", "0", ""
|
|
"Temperature", "C", "15", "1", ""
|
|
"Humidity", "RH", "15", "0", ""
|
|
"Relay status", "Relay", "1", "0", "
|
|
This indicator monitor the software relay status, whereas the yellow/gray wiring monitor the hardware relay status
|
|
(it's actual output). Both methods are good, just different. The software way of monitoring the status might be up
|
|
to 1 second longer (if delay is 1 sec) due to the fact that a switch status is send instant compared to the relay
|
|
status indicator which is sent once every X seconds.
|
|
"
|
|
"Temperature adjustment", "Level", "1", "0", "
|
|
Only available in some versions of the tSense.
|
|
|
|
This raw value goes from 0 - 1000 in 9 steps.
|
|
To have them displayed as -4 to 4 use this formula:
|
|
|
|
``%value%*0.008-4``
|
|
|
|
To have them displayed as 1 to 9 use this formula:
|
|
|
|
``%value%*0.008+1``
|
|
"
|
|
"ABC period", "N/A", "", "", ""
|
|
|
|
.. note:: If you want to use the relative carbon dioxide percentage (2000ppm = 100% and 350ppm = 0%) you should use this
|
|
:code:`100-(2000-%value%)/(2000-350)*100` as a formula. And instead of :code:`ppm` as value name you should use
|
|
:code:`RCO2` (relative CO2) and 1 decimal.
|
|
|
|
Rules examples
|
|
--------------
|
|
|
|
.. code-block:: none
|
|
|
|
on CO2#Level do
|
|
if [CO2#Level]>2000
|
|
Publish,%sysname%/Alarm,CO2 level is too high!
|
|
endif
|
|
endon
|
|
|
|
Commands available
|
|
~~~~~~~~~~~~~~~~~~
|
|
|
|
.. include:: P052_commands.repl
|
|
|
|
Where to buy
|
|
------------
|
|
|
|
.. csv-table::
|
|
:header: "Store", "Link"
|
|
:widths: 5, 40
|
|
|
|
"Senseair","`Link 1 <https://senseair.com/products/tsense/tsense-display/>`_"
|
|
|
|
|affiliate|
|
|
|
|
|
|
More pictures
|
|
-------------
|
|
|
|
There's two main ones, the EFA model and the standard model (see different GUI below).
|
|
The hardware is the same (K70) but different firmware separates them. No one is better then the other, they are just different.
|
|
|
|
The EFA model of tSense generally displays the temperature and carbon dioxide level. Other than that you have a
|
|
software button for controlling the internal relay (on and off). It even have a 9 step slider used to control the
|
|
indoor temperature (monitoring the status of this slider is possible using the plugin).
|
|
|
|
.. image:: P052_tSense_K70_2.jpg
|
|
|
|
The standard model of tSense display temperature, humidity and carbon dioxide level on the main page.
|
|
The relay can only be set to trigger by the settings menu where you can have a target level where the relay will activate.
|
|
|
|
.. image:: P052_tSense_K70_1.jpg
|
|
|
|
Mounting the D1 mini inside enclosure
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
When you first open up the housing you find this:
|
|
|
|
.. image:: P052_tSense_K70_3.jpg
|
|
|
|
Remove the plastic cover to expose the pcb-board:
|
|
|
|
.. image:: P052_tSense_K70_4.jpg
|
|
|
|
To get power and ground to the ESP we hi-jack these vias:
|
|
|
|
.. image:: P052_tSense_K70_5.jpg
|
|
|
|
Connect these to the ESPs 5V and G:
|
|
|
|
.. image:: P052_tSense_K70_6.jpg
|
|
|
|
The ESP monitor the tSense through the serial ports, green to D7 (GPIO-13) and white to D8 (GPIO-15):
|
|
|
|
.. image:: P052_tSense_K70_7.jpg
|
|
|
|
Use the 3.5mm pads or the vias on the tSense:
|
|
|
|
.. image:: P052_tSense_K70_8.jpg
|
|
|
|
.. image:: P052_tSense_K70_9.jpg
|
|
|
|
.. image:: P052_tSense_K70_10.jpg
|
|
|
|
Monitoring the relay (hard wired)
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
.. image:: P052_tSense_K70_11.jpg
|
|
|
|
.. image:: P052_tSense_K70_12.jpg
|
|
|
|
.. image:: P052_tSense_K70_13.jpg
|
|
|
|
.. note::
|
|
Please observe that you cannot CONTROL the relay using this method, only monitor its status.
|
|
To control the relay you need the latest plugin and use ``senseair_setrelay`` command.
|
|
|
|
To fixate the ESP board you could use a tape pad with double sided adhesive:
|
|
|
|
.. image:: P052_tSense_K70_14.jpg
|
|
|
|
Before re-positioning the unit onto the back panel you need to remove a plastic wall (just bend it and it will break):
|
|
|
|
.. image:: P052_tSense_K70_15.jpg
|
|
|
|
.. image:: P052_tSense_K70_16.jpg
|
|
|
|
DONE! Power up using the tSense's 24VDC/24VAC (the unit is possible to function with input power
|
|
9VDC - 24VDC with no problem) power adaptor.
|