mirror of
https://github.com/letscontrolit/ESPEasy.git
synced 2026-09-12 09:36:59 +00:00
79 lines
2.1 KiB
ReStructuredText
79 lines
2.1 KiB
ReStructuredText
.. include:: ../Plugin/_plugin_substitutions_p09x.repl
|
|
.. _P092_ESR21_page:
|
|
|
|
ESR21
|
|
=====
|
|
|
|
|P092_typename|
|
|
|P092_status|
|
|
|
|
Introduction
|
|
------------
|
|
|
|
The ESR21 unit is a simple solar control.
|
|
|
|
The ESR21 unit is a differential control that can be used in many ways
|
|
|
|
* The DL bus runs at 12 volts.
|
|
* The data frame consist of 30 bytes (excluding sync and CRC).
|
|
* The data are transmitted @ 488Hz, therefore the transmission of one data set takes about 0.67 seconds.
|
|
|
|
.. image:: P092_ESR21.png
|
|
|
|
Wiring
|
|
------
|
|
|
|
.. image:: P092_12V_Wiring.png
|
|
|
|
Protocol
|
|
--------
|
|
|
|
.. image:: P092_ESR21_Protocol.png
|
|
|
|
Setup
|
|
-----
|
|
|
|
.. note:: A new device task must be created for each value to be read from the DL bus!
|
|
|
|
.. image:: P092_Setup.png
|
|
|
|
Task settings
|
|
~~~~~~~~~~~~~
|
|
|
|
* **Device**: Heating - DL-Bus (Technische Alternative)
|
|
* **Name**: Name of the task (example name **ValueN**, where N is a number).
|
|
* **Enable**: Should the task be enabled or not
|
|
|
|
Sensor
|
|
^^^^^^
|
|
|
|
* **1st GPIO**: DL bus input e.g. **GPIO 14 (D5)**
|
|
* **DL-Bus Type**: **ESR21**
|
|
|
|
.. note:: The settings for **1st GPIO** and **DL-Bus Type** must be the same for all used DL bus tasks!
|
|
|
|
Inputs
|
|
^^^^^^
|
|
|
|
.. note:: The description of the **Frame data** and the related **Frame bytes** can be found in the section **Protocol**!
|
|
|
|
.. csv-table::
|
|
:header: "Frame data", "Frame bytes", "Value", "Index", "Decimals"
|
|
:widths: 16, 8, 8, 5, 5
|
|
|
|
"Sensor1 ... Sensor3", "3 ... 8", "Sensor", "1 - 3", "1"
|
|
"Ext1 ... Ext6", "9 ... 20", "Ext. Sensor", "1 - 6", "1"
|
|
"Output byte", "21", "Digital Output", "", "0"
|
|
"Speed step", "22", "Speed step", "", "0"
|
|
"Analog output", "23", "Analog output", "", "1"
|
|
"Current power", "25,26", "Heat power [kW]", "", "1"
|
|
"Heat quantity", "27 ... 30", "Heat meter [MWh]", "", "4"
|
|
|
|
Data acquisition
|
|
^^^^^^^^^^^^^^^^
|
|
|
|
* **Send to controller** 1..3: Check which controller (if any) you want to publish to. All or no controller can be used.
|
|
* **Interval**: How often should the task publish its value (10..60 seconds is normal).
|
|
|
|
.. note:: Interval not less than **10 seconds**! The reading of the DL bus happens twice per interval.
|