.. include:: ../Plugin/_plugin_substitutions_p13x.repl
|
|
.. _P133_page:
|
|
|
|
|P133_typename|
|
|
==================================================
|
|
|
|
|P133_shortinfo|
|
|
|
|
Plugin details
|
|
--------------
|
|
|
|
Type: |P133_type|
|
|
|
|
Name: |P133_name|
|
|
|
|
Status: |P133_status|
|
|
|
|
GitHub: |P133_github|_
|
|
|
|
Maintainer: |P133_maintainer|
|
|
|
|
Used libraries: |P133_usedlibraries|
|
|
|
|
Description
|
|
-----------
|
|
|
|
I2C UV and Ambient light sensor with UVIndex and Lux calculation.
|
|
|
|
Configuration
|
|
--------------
|
|
|
|
.. image:: P133_DeviceConfiguration.png
|
|
:alt: Device configuration
|
|
|
|
* **Name** A unique name should be entered here.
|
|
|
|
* **Enabled** The device can be disabled or enabled. When not enabled the device should not use any resources.
|
|
|
|
I2C Options
|
|
^^^^^^^^^^^^
|
|
|
|
The available settings here depend on the build used. At least the **Force Slow I2C speed** option is available, but selections for the I2C Multiplexer can also be shown. For details see the :ref:`Hardware_page`
|
|
|
|
Device Settings
|
|
^^^^^^^^^^^^^^^^
|
|
|
|
* **Read mode**: As the sensor has 2 measuring options, the kind of measurement can be selected. By default, Dual mode is selected.
|
|
|
|
Available options:
|
|
|
|
.. image:: P133_ReadModeOptions.png
|
|
:alt: Read mode options
|
|
|
|
* **Dual mode, read alternating UV/Ambient** Read both UV and Ambient alternating, and apply separate settings for Gain and Resolution when switching the measuring mode. Calculates both the UVIndex and Lux values.
|
|
* **UV reading only** Read only UV, and calculate the UVIndex from it (according to manufacurer specification).
|
|
* **Ambient reading only** Read Ambient light sensor value (ALS), and calculate the Lux value from that.
|
|
|
|
When selecting a different Read mode, the settings will be saved and the page reloaded, as the available options change when choosing a different option.
|
|
|
|
.. image:: P133_UVConfiguration.png
|
|
:alt: UV Only configuration
|
|
|
|
.. image:: P133_ALSConfiguration.png
|
|
:alt: Ambient Only configuration
|
|
|
|
* **UV Gain** The Gain determains the amplification of the signal measured. Depending on the desired range of values, this can be adjusted.
|
|
* **Ambient Gain**
|
|
|
|
.. image:: P133_GainOptions.png
|
|
:alt: Gain options
|
|
|
|
* **UV Resolution** The sensor is capable of returning the measurement in different resolutions, as selected here.
|
|
* **Ambient Resolution**
|
|
|
|
.. image:: P133_ResolutionOptions.png
|
|
:alt: Resolution options
|
|
|
|
The time that is needed to determine the measurement increases with the resolution selected. The sensor is only read if a new measurement is actually available.
|
|
|
|
The Gain and Resolution are factored in for the calculation of the UVIndex and Lux values.
|
|
|
|
Data Acquisition
|
|
^^^^^^^^^^^^^^^^
|
|
|
|
This group of settings, **Single event with all values**, **Send to Controller** and **Interval** settings are standard available configuration items. Send to Controller is only visible when one or more Controllers are configured.
|
|
|
|
**Interval** By default, Interval will be set to 60 sec. It is the frequency used to read sensor values and send these to any Controllers configured for this device.
|
|
|
|
Values
|
|
^^^^^^
|
|
|
|
The measured values are available in ``UV`` and ``Ambient``, and the calculated values in ``UVIndex`` and ``Lux``. A formula can be set to recalculate. The number of decimals is by default set to 0 for UV and Ambient, as decimals are not available from the sensor, but after calculating the UVIndex and Lux they are.
|
|
|
|
.. Commands
|
|
.. ~~~~~~~~
|
|
|
|
.. .. include:: P133_commands.repl
|
|
|
|
|
|
|
|
Change log
|
|
----------
|
|
|
|
.. versionchanged:: 2.0
|
|
|
|
|added| 2022-03-26 Initially added.
|