UVR31
=====
|P092_typename|
|P092_status|
Introduction
------------
The UVR31 unit is a single-circuit universal control system.
The UVR31 unit is designed for simple solar installations and heating systems (storage charging, domestic hot water preparation)
* The DL bus runs at 24 volts.
* The data frame consist of 8 bytes (excluding sync).
* The data are transmitted @ 50Hz, therefore the transmission of one data set takes about 1.92 seconds.
.. image:: P092_UVR31.png
Wiring
------
.. image:: P092_24V_Wiring.png
Protocol
--------
.. image:: P092_UVR31_Protocol.png
Setup
-----
.. note:: A new device task must be created for each value to be read from the DL bus!
.. image:: P092_Setup.png
Task settings
~~~~~~~~~~~~~
* **Device**: Heating - DL-Bus (Technische Alternative)
* **Name**: Name of the task (example name **ValueN**, where N is a number).
* **Enable**: Should the task be enabled or not
Sensor
^^^^^^
* **1st GPIO**: DL bus input e.g. **GPIO 14 (D5)**
* **DL-Bus Type**: **UVR31**
.. note:: The settings for **1st GPIO** and **DL-Bus Type** must be the same for all used DL bus tasks!
Inputs
^^^^^^
.. note:: The description of the **Frame data** and the related **Frame bytes** can be found in the section **Protocol**!
.. csv-table::
:header: "Frame data", "Frame bytes", "Value", "Index", "Decimals"
:widths: 16, 8, 8, 5, 5
"Temp1 ... Temp3", "2 ... 7", "Sensor", "1 - 3", "1"
"Output byte", "8", "Digital Output", "", "0"
Data acquisition
^^^^^^^^^^^^^^^^
* **Send to controller** 1..3: Check which controller (if any) you want to publish to. All or no controller can be used.
* **Interval**: How often should the task publish its value (20..60 seconds is normal).
.. note:: Intervall not less than **20 seconds**! The reading of the DL bus happens twice per intervall.