Arduino
#include "_Plugin_Helper.h"
|
|
#ifdef USES_P088
|
|
//#######################################################################################################
|
|
//#################################### Plugin 088: Heatpump IR ##########################################
|
|
//#######################################################################################################
|
|
|
|
#define PLUGIN_088
|
|
#define PLUGIN_ID_088 88
|
|
#define PLUGIN_NAME_088 "Energy (Heat) - Heatpump IR transmitter [TESTING]"
|
|
|
|
|
|
/*
|
|
* ESPEasy plugin to send air conditioner / heatpump IR signals
|
|
* * Use the device type 'Heatpump IR transmitter' as the device type in Devices -> Edit
|
|
* * Connect and IR LED + series resistor between the GPIO pin configured for this device and ground
|
|
* * This is not a standalone plugin, also the _C002.ino modification is needed for Domoticz MQTT to work
|
|
*
|
|
* Send commands through http, like this example (assuming the IP address of the ESP node is 192.168.0.61):
|
|
* * curl http://192.168.0.61/control?cmd=heatpumpir,panasonic_ckp,1,1,0,22,0,0
|
|
*
|
|
* Send commands through OpenHAB MQTT with Mosquitto, like this example,
|
|
* assuming the 'Name' of the ESP node in ESPEasy Main Settings page is 'ESP_Easy')
|
|
* * mosquitto_pub -t /ESP_Easy/cmd -m heatpumpir,panasonic_ckp,1,1,0,22,0,0
|
|
*
|
|
* Send commands through Domoticz MQTT, like this example,
|
|
* assuming the IDX of the heatpump device in both Domoticz and ESP Easy is 13:
|
|
* * Create a 'Dummy' hardware in Domoticz, create a 'Text' virtual sensor into the 'Dummy' device (assumed we got IDX 13)
|
|
* * Define the Domoticz MQTT protocol in ESP Easy, define the 'Heatpump IR transmitter' device using the same IDX as in Domoticz
|
|
* * Update the 'Text' sensor using the Domoticz API, like navigating to this URL (assuming Domoticz is at 192.168.0.5:8080):
|
|
* * http://192.168.0.5:8080/json.htm?type=command¶m=udevice&idx=13&svalue=panasonic_ckp,1,1,0,22,0,0
|
|
*
|
|
* Take a look at https://github.com/ToniA/cabin-village-project/blob/eventscripts/script_device_hp.lua for Domoticz event examples
|
|
*
|
|
* The parameters are (in this order)
|
|
* * The type of the heatpump as a string, see the implementations of different models, like https://github.com/ToniA/arduino-heatpumpir/blob/master/MitsubishiHeatpumpIR.cpp
|
|
* * power state (see https://github.com/ToniA/arduino-heatpumpir/blob/master/HeatpumpIR.h for modes)
|
|
* * operating mode
|
|
* * fan speed
|
|
* * temperature
|
|
* * vertical air direction
|
|
* * horizontal air direction
|
|
*
|
|
* See the HeatpumpIR library for further information: https://github.com/ToniA/arduino-heatpumpir
|
|
*
|
|
*/
|
|
|
|
#include <HeatpumpIRFactory.h>
|
|
|
|
IRSenderIRremoteESP8266 *Plugin_088_irSender = nullptr;
|
|
int panasonicCKPTimer = 0;
|
|
|
|
boolean Plugin_088(uint8_t function, struct EventStruct *event, String& string)
|
|
{
|
|
boolean success = false;
|
|
|
|
switch (function)
|
|
{
|
|
case PLUGIN_DEVICE_ADD:
|
|
{
|
|
Device[++deviceCount].Number = PLUGIN_ID_088;
|
|
Device[deviceCount].Type = DEVICE_TYPE_SINGLE;
|
|
Device[deviceCount].VType = Sensor_VType::SENSOR_TYPE_NONE;
|
|
Device[deviceCount].Ports = 0;
|
|
Device[deviceCount].PullUpOption = false;
|
|
Device[deviceCount].InverseLogicOption = false;
|
|
Device[deviceCount].FormulaOption = false;
|
|
Device[deviceCount].ValueCount = 0;
|
|
Device[deviceCount].SendDataOption = false;
|
|
Device[deviceCount].TimerOption = false;
|
|
Device[deviceCount].TimerOptional = false;
|
|
Device[deviceCount].GlobalSyncOption = false;
|
|
Device[deviceCount].DecimalsOnly = false;
|
|
|
|
break;
|
|
}
|
|
|
|
case PLUGIN_GET_DEVICENAME:
|
|
{
|
|
string = F(PLUGIN_NAME_088);
|
|
break;
|
|
}
|
|
|
|
case PLUGIN_GET_DEVICEVALUENAMES:
|
|
{
|
|
break;
|
|
}
|
|
|
|
case PLUGIN_WEBFORM_LOAD:
|
|
{
|
|
// We need the index of the controller we are: 0-CONTROLLER_MAX
|
|
// FIXME TD-er: Why looking for Domoticz MQTT? Other plugins also support IDX values.
|
|
controllerIndex_t controllerNr = 0;
|
|
for (controllerIndex_t i=0; i < CONTROLLER_MAX; i++)
|
|
{
|
|
if (Settings.Protocol[i] == 2) { controllerNr = i; }
|
|
}
|
|
|
|
if (Settings.ControllerEnabled[controllerNr])
|
|
{
|
|
addHtml(F("<TR><TD>IDX:<TD>"));
|
|
String id = F("TDID"); //="taskdeviceid"
|
|
id += controllerNr + 1;
|
|
addNumericBox(id, Settings.TaskDeviceID[controllerNr][event->TaskIndex], 0, 9999);
|
|
}
|
|
success = true;
|
|
break;
|
|
}
|
|
|
|
case PLUGIN_WEBFORM_SAVE:
|
|
{
|
|
success = true;
|
|
break;
|
|
}
|
|
|
|
case PLUGIN_INIT:
|
|
{
|
|
int irPin = Settings.TaskDevicePin1[event->TaskIndex];
|
|
if (validGpio(irPin))
|
|
{
|
|
addLog(LOG_LEVEL_INFO, F("P088: Heatpump IR transmitter activated"));
|
|
if (Plugin_088_irSender != nullptr)
|
|
{
|
|
delete Plugin_088_irSender;
|
|
}
|
|
Plugin_088_irSender = new (std::nothrow) IRSenderIRremoteESP8266(irPin);
|
|
}
|
|
if (Plugin_088_irSender != nullptr && irPin == -1)
|
|
{
|
|
addLog(LOG_LEVEL_INFO, F("P088: Heatpump IR transmitter deactivated"));
|
|
delete Plugin_088_irSender;
|
|
Plugin_088_irSender = nullptr;
|
|
}
|
|
success = true;
|
|
break;
|
|
}
|
|
|
|
case PLUGIN_READ:
|
|
{
|
|
success = true;
|
|
break;
|
|
}
|
|
|
|
case PLUGIN_WRITE:
|
|
{
|
|
String heatpumpModel;
|
|
unsigned int powerMode = POWER_ON;
|
|
unsigned int operatingMode = MODE_HEAT;
|
|
unsigned int fanSpeed = FAN_2;
|
|
unsigned int temperature = 22;
|
|
unsigned int vDir = VDIR_UP;
|
|
unsigned int hDir = HDIR_AUTO;
|
|
|
|
String cmd = parseString(string, 1);
|
|
if (cmd.equalsIgnoreCase(F("HEATPUMPIR")) && Plugin_088_irSender != nullptr)
|
|
{
|
|
String TmpStr1;
|
|
if (GetArgv(string.c_str(), TmpStr1, 2)) heatpumpModel = TmpStr1;
|
|
if (GetArgv(string.c_str(), TmpStr1, 3)) powerMode = str2int(TmpStr1.c_str());
|
|
if (GetArgv(string.c_str(), TmpStr1, 4)) operatingMode = str2int(TmpStr1.c_str());
|
|
if (GetArgv(string.c_str(), TmpStr1, 5)) fanSpeed = str2int(TmpStr1.c_str());
|
|
if (GetArgv(string.c_str(), TmpStr1, 6)) temperature = str2int(TmpStr1.c_str());
|
|
if (GetArgv(string.c_str(), TmpStr1, 7)) vDir = str2int(TmpStr1.c_str());
|
|
if (GetArgv(string.c_str(), TmpStr1, 8)) hDir = str2int(TmpStr1.c_str());
|
|
#ifdef IR_SEND_TIME
|
|
sendHour = node_time.hour();
|
|
sendMinute = node_time.minute();
|
|
sendWeekday = node_time.weekday();
|
|
#endif
|
|
HeatpumpIR *heatpumpIR = HeatpumpIRFactory::create(heatpumpModel.c_str());
|
|
|
|
if (heatpumpIR != nullptr) {
|
|
enableIR_RX(false);
|
|
heatpumpIR->send(*Plugin_088_irSender, powerMode, operatingMode, fanSpeed, temperature, vDir, hDir);
|
|
enableIR_RX(true);
|
|
|
|
delete heatpumpIR;
|
|
heatpumpIR = nullptr;
|
|
|
|
addLog(LOG_LEVEL_INFO, F("P088: Heatpump IR code transmitted"));
|
|
#ifdef IR_DEBUG_PACKET
|
|
addLog(LOG_LEVEL_DEBUG, IRPacket);
|
|
#endif
|
|
if (printToWeb)
|
|
{
|
|
printWebString += F("P088: Heatpump IR code transmitted");
|
|
#ifdef IR_DEBUG_PACKET
|
|
printWebString += F(" <BR>\n"); // do both <BR> and \n to break line both in browser and curl -s
|
|
printWebString += IRPacket;
|
|
printWebString += F("\n");
|
|
#endif
|
|
}
|
|
|
|
// Panasonic CKP can only be turned ON/OFF by using the timer,
|
|
// so cancel the timer in 2 minutes, after the heatpump has turned on or off
|
|
if (strcmp_P(heatpumpModel.c_str(), PSTR("panasonic_ckp")) == 0)
|
|
{
|
|
panasonicCKPTimer = 120;
|
|
}
|
|
|
|
success = true;
|
|
}
|
|
}
|
|
break;
|
|
}
|
|
|
|
case PLUGIN_EXIT:
|
|
{
|
|
addLog(LOG_LEVEL_INFO, F("P088: Heatpump IR transmitter deactivated"));
|
|
|
|
if (Plugin_088_irSender != nullptr)
|
|
{
|
|
delete Plugin_088_irSender;
|
|
Plugin_088_irSender = nullptr;
|
|
}
|
|
|
|
break;
|
|
}
|
|
|
|
case PLUGIN_ONCE_A_SECOND:
|
|
{
|
|
if (panasonicCKPTimer > 0)
|
|
{
|
|
panasonicCKPTimer--;
|
|
if (panasonicCKPTimer == 0)
|
|
{
|
|
PanasonicCKPHeatpumpIR *panasonicHeatpumpIR = new (std::nothrow) PanasonicCKPHeatpumpIR();
|
|
if (panasonicHeatpumpIR != nullptr) {
|
|
enableIR_RX(false);
|
|
panasonicHeatpumpIR->sendPanasonicCKPCancelTimer(*Plugin_088_irSender);
|
|
enableIR_RX(true);
|
|
|
|
delete panasonicHeatpumpIR;
|
|
addLog(LOG_LEVEL_INFO, F("P088: The TIMER led on Panasonic CKP should now be OFF"));
|
|
}
|
|
}
|
|
}
|
|
success = true;
|
|
break;
|
|
}
|
|
|
|
case PLUGIN_TEN_PER_SECOND:
|
|
{
|
|
success = true;
|
|
break;
|
|
}
|
|
}
|
|
|
|
return success;
|
|
}
|
|