mirror of
https://github.com/letscontrolit/ESPEasy.git
synced 2026-09-12 09:36:59 +00:00
22 lines
802 B
Plaintext
22 lines
802 B
Plaintext
.. csv-table::
|
|
:header: "Command Syntax", "Extra information"
|
|
:widths: 20, 30
|
|
|
|
"
|
|
``radsens,calibration,<value>``
|
|
","
|
|
Change the calibration value for the board in impulses per microrad. Can be used when a different type of geiger tube is installed on the board. The default tube uses 105 imp/uRad.
|
|
"
|
|
"
|
|
``radsens,highvoltage,<0|1>``
|
|
","
|
|
Enable (``1``) or disable (``0``) the High Voltage generator on the board that powers the geiger tube. When this is turned off, the used power is greatly reduced, but no usable measurements can be retrieved.
|
|
|
|
This command can be used when bringing the ESP in sleep mode, and when returning from sleep mode.
|
|
"
|
|
"
|
|
``radsens,resetcount``
|
|
","
|
|
Clear the incremental count in the sensor driver.
|
|
"
|