.. include:: ../Plugin/_plugin_substitutions_p11x.repl
|
|
.. _P114_page:
|
|
|
|
|P114_typename|
|
|
==================================================
|
|
|
|
|P114_shortinfo|
|
|
|
|
Plugin details
|
|
--------------
|
|
|
|
Type: |P114_type|
|
|
|
|
Name: |P114_name|
|
|
|
|
Status: |P114_status|
|
|
|
|
GitHub: |P114_github|_
|
|
|
|
Maintainer: |P114_maintainer|
|
|
|
|
Used libraries: |P114_usedlibraries|
|
|
|
|
Description
|
|
-----------
|
|
|
|
This I2C sensor with 2 resolutions (normal/high dynamic) offers UVA (365 +/-10 nm) and UVB (330 +/-10 nm) measurement and a calculated UVIndex value. Output result for UV is in irradiance, watt per square metre. The maximum value that can me measured is 65535, as the chip provides 16 bit values.
|
|
|
|
NB: If the unit is over-exposed, possibly the measurement could exceed the maximum returned value of 65535, and the calculated UVIndex value will *not* be correct.
|
|
|
|
NB2: When measuring outside UV exposure, the sensor should also be outside, as f.e. window glass filters out most UV radiance, and measurements will be (very) inaccurate.
|
|
|
|
Configuration
|
|
--------------
|
|
|
|
.. image:: P114_DeviceConfiguration.png
|
|
|
|
**Name** A unique name should be entered here.
|
|
|
|
**Enabled** The device can be disabled or enabled. When not enabled the device should not use any resources.
|
|
|
|
I2C Options
|
|
^^^^^^^^^^^^
|
|
|
|
The available settings here depend on the build used. At least the **Force Slow I2C speed** option is available, but selections for the I2C Multiplexer can also be shown. For details see the :ref:`Hardware_page`
|
|
|
|
**I2C Address**: The address the device is using. Depending on the board used, when available a SDO pin, or soldering a 0 ohm resistor on a different location, can be used to select the used address. If that address selection is not available, then an I2C multiplexer (in a matching ESPEasy build) can be used to use multiple sensors on a single ESPEasy unit.
|
|
|
|
Device Settings
|
|
^^^^^^^^^^^^^^^^
|
|
|
|
**Integration Time**: The integration time setting of the sensor determines the accuracy of the measurement. There are 5 options available:
|
|
|
|
.. image:: P114_IntegrationTime.png
|
|
|
|
*50 ms* The default value, using an integration time of 50 msec.
|
|
|
|
*100ms*
|
|
|
|
*200ms*
|
|
|
|
*400ms*
|
|
|
|
*800ms*
|
|
|
|
Usually a higher integration time results in a more accurate measurement.
|
|
|
|
**Dynamic Setting**: This determines the dynamic setting:
|
|
|
|
.. image:: P114_DynamicSetting.png
|
|
|
|
*Normal Dynamic*
|
|
|
|
*High Dynamic* For better response to changing conditions during measurement.
|
|
|
|
|
|
|
|
.. include:: DataAcquisition.repl
|
|
|
|
**Interval** By default, Interval will be set to 60 sec. The minimum value allowed is 1 sec. but for measuring UV values, that don't change very quickly, reasonable values should be between 10 and 300 sec.
|
|
|
|
Values
|
|
^^^^^^
|
|
|
|
The measured values are available in ``UVA``, ``UVB`` and ``UCIndex``. A formula can be set to recalculate. The number of decimals is by default set to 2, and can be set to 0 for ``UVA`` and ``UVB``, as no decimals are provided from the measurement. ``UVIndex`` value is often used without decimals, but can be set as desired.
|
|
|
|
.. Events
|
|
.. ~~~~~~
|
|
|
|
.. .. include:: P114_events.repl
|
|
|
|
|
|
|
|
Change log
|
|
----------
|
|
|
|
.. versionchanged:: 2.0
|
|
|
|
|added| 2021-04-24 Moved to main repository as Plugin 114 UV - VEML6075 UVA/UVB Sensor from the ESPEasyPluginPlayground (P130).
|