.. csv-table::
:header: "Command", "Extra information"
:widths: 20, 30
"
``tarechana``
","
Use the last measured value for Channel A as the Offset/Tare value.
NB: Use ``save`` to actually save this as the new Offset. Saving the value is not required, 0-calibration should be applied after every start of the device, and on a regular basis, because external influences on the load cell will (slightly) change measurements.
"
"
``tarechanb``
","
Use the last measured value for Channel B as the Offset/Tare value.
NB: Use ``save`` to actually save this as the new Offset.
NB2: When setting the Tare for both A and B channel, use ``save`` after setting *both* values, to reduce wear of the ESP Flash memory.
"