.. include:: ../Plugin/_plugin_substitutions_p05x.repl
|
|
.. _P052_page:
|
|
|
|
|P052_typename|
|
|
==================================================
|
|
|
|
|P052_shortinfo|
|
|
|
|
Plugin details
|
|
--------------
|
|
|
|
Type: |P052_type|
|
|
|
|
Port Type: |P052_porttype|
|
|
|
|
Name: |P052_name|
|
|
|
|
Status: |P052_status|
|
|
|
|
GitHub: |P052_github|_
|
|
|
|
Maintainer: |P052_maintainer|
|
|
|
|
Used libraries: |P052_usedlibraries|
|
|
|
|
Description
|
|
-----------
|
|
|
|
SenseAir is a Swedish manufacturer known for their CO2 sensors.
|
|
|
|
Below, in the "Supported Hardware" section, are links to a number of their sensors.
|
|
|
|
CO2 is a gas which we humans exhale. It is also formed as a by-product from burning any carbon based substance.
|
|
For example, burning gas or wood.
|
|
|
|
It is important to keep CO2 levels low to create a healthy indoor climate.
|
|
Typically one would aim for an indoor CO2 concentration of less than 700 ppm.
|
|
|
|
The outdoor global CO2 levels are about 411 ppm and rising quite fast.
|
|
|
|
|
|
Calibration
|
|
-----------
|
|
|
|
As with any sensor, CO2 sensors need calibration.
|
|
That's why CO2 sensors are calibrated at the factory using highly specialized chambers with full control of the air entering those chambers.
|
|
|
|
.. warning:: Do NOT!!! try to calibrate using the bCAL pin on the CO2 sensor, unless you know what you're doing.
|
|
Many sensors may already have been destroyed or at least have their factory calibration cleared by improper calibration.
|
|
|
|
CO2 sensors have at least two important calibration points:
|
|
|
|
* 0 ppm, where the sensor is placed in a gas which contains no CO2.
|
|
* 400 ppm, which is an approximation of the global CO2 levels (sadly already outdated).
|
|
|
|
Apparently a number of sites and/or blogs instruct users to pull the bCAL pin to GND for a certain amount of time.
|
|
On SenseAir sensors, this may trigger one of these calibration points to be set:
|
|
|
|
* 4 ... 8 seconds: The current CO2 levels will be assumed to be the new "400 ppm" level.
|
|
* 16+ seconds: The current CO2 levels will be assumed to be the new "0 ppm" level.
|
|
|
|
As may be clear from the warning above, one should **NOT** try to do this!!
|
|
|
|
It is very hard to create a proper 400 ppm CO2 concentration as simply breathing near the sensor will cause a significant rise in CO2 concentration.
|
|
|
|
Other factors affecting the CO2 levels:
|
|
|
|
* Industrial areas.
|
|
* Busy roads.
|
|
* Being in a city.
|
|
* Near plants while the sun has set. (plants convert CO2 into O2 due to sunlight, but this process reverses while the sun has set)
|
|
* Close to something burning. (e.g. cooking using gas, burning candles, wood fire, etc.)
|
|
* Living creatures, like humans or animals.
|
|
|
|
A NDIR CO2 sensor generates IR light of a specific wave length and measures the absorption of this light.
|
|
Thus direct sunlight and/or heat from a stove, heater, etc. may affect CO2 measurements as this is adding extra IR light into the measurement.
|
|
|
|
CO2 sensors typically have an Automatic Base Calibration mode (sometimes referred to as ABC mode, but it is unsure whether this is a trademarked name).
|
|
With this mode enabled, the sensor keeps track of the minimal raw sensor value seen in some time period (e.g. 1 week).
|
|
This new value is then considered to be the new 400 ppm value.
|
|
SenseAir sensors will not immediately jump to this value if it differs a lot from the current value.
|
|
So it may take several weeks (sometimes months) for a sensor to correct an incorrect 400 ppm level calibration.
|
|
|
|
Therefore, again the warning: **Do NOT perform manual calibration using the bCAL pin**
|
|
|
|
It may seem a bit strange to put all those warnings here, but it really happens a lot that people immediately start to damage CO2 sensors by trying to calibrate them while there is nothing wrong with the sensors.
|
|
It is unclear as to why this happens to CO2 sensors over-and-over again.
|
|
Maybe there is some popular blog out there instructing readers to do so.
|
|
|
|
But please, **DO NOT CALIBRATE CO2 SENSORS using the bCAL pin**
|
|
|
|
Supported hardware
|
|
------------------
|
|
|
|
.. .. |P052_usedby|
|
|
|
|
:ref:`P052_S8_page`
|
|
|
|
:ref:`P052_S11_page`
|
|
|
|
:ref:`P052_tSense_K70_page`
|
|
|
|
Sensor
|
|
^^^^^^
|
|
|
|
See: :ref:`SerialHelper_page`
|
|
|
|
Commands available
|
|
^^^^^^^^^^^^^^^^^^
|
|
|
|
.. include:: P052_commands.repl
|
|
|
|
.. Events
|
|
.. ~~~~~~
|
|
|
|
.. .. include:: P052_events.repl
|
|
|
|
Change log
|
|
----------
|
|
|
|
.. versionchanged:: 2.0
|
|
...
|
|
|
|
|added|
|
|
Major overhaul for 2.0 release.
|
|
|
|
.. versionadded:: 1.0
|
|
...
|
|
|
|
|added|
|
|