Description
-----------
I2C Power management controller. As found in some ESP32 models of M5Stack and TTGO.
Plugin is only available in ESP32 builds, as the library uses some software constructs that aren't available for ESP8266, and this controller is currently only found to be used with ESP32 boards.
Configuration
--------------
.. image:: P137_DeviceConfiguration.png
:alt: Device configuration
* **Name** A unique name should be entered here.
* **Enabled** The device can be disabled or enabled. When not enabled the device should not use any resources.
I2C Options
^^^^^^^^^^^^
The available settings here depend on the build used. At least the **Force Slow I2C speed** option is available, but selections for the I2C Multiplexer can also be shown. For details see the :ref:`Hardware_page`
Device Settings
^^^^^^^^^^^^^^^^
Output Configuration
^^^^^^^^^^^^^^^^^^^^
* **Number Output Values**: Select the number of values that have to be available. The default is set to *Quad*, as there are far more than 4 values available for display.
Available options: *Single* (1), *Dual* (2), *Triple* (3) and *Quad* (4).
* **Value 1..4**: Select the desired value to be available in the Values fields. The name of the Values will be set to a matching default automatically, but can be changed afterward.
.. image:: P137_ValueOptions.png
Available options:
* *None*: To leave the value empty/0.00
* *Battery voltage*: The voltage measured at the Battery connection.
* *Battery discharge current*: The current that the battery is being discharged with.
* *Battery charge current*: The current that the battery is being charged with.
* *Battery power*: The power available from the battery.
* *Input voltage*: The input voltage for the controller.
* *Input current*: The input current used by the controller.
* *VBus voltage*: The voltage at the VBus output.
* *VBus current*: The current delivered via the VBus output.
* *Internal temperature*: The internal chip temperature.
* *APS Voltage*: The voltage at the APS output.
* *LDO2 voltage*: The voltage at the LDO2 output.
* *LDO3 voltage*: The voltage at the LDO3 output.
* *GPIO0 voltage*: The voltage at the GPIO0 (on AXP192, not ESP!) output.
.. note:: Not all options hold usable values for all boards, some may even be not connected. Check the board documentation for available values.
* **Decimals for config values**: The number of decimals to use for presenting the Config values (see below for a list of available values).
Hardware outputs AXP192
^^^^^^^^^^^^^^^^^^^^^^^
The **LDO2**, **LDO3** and **GPIO0** outputs of the AXP192 can be set at a predefined value. When setting a value below 1800 mV, the output will be turned off. Above 3300 mV is not supported/allowed. Stepsize/resolution is ca. 100 mV.
.. warning:: Check board documentation for what each output is actually connected to, and the allowed voltage range for that output.
.. note:: AXP192 output pins ``DCDC1`` .. ``DCDC3`` are usually hardwired to specific functions of the board and/or should not be changed, and ``GPIO1`` .. ``GPIO4`` are often unused, *and* currently not implemented in the used library, so are not (yet) available for configuration.
Data Acquisition
^^^^^^^^^^^^^^^^
This group of settings, **Single event with all values**, **Send to Controller** and **Interval** settings are standard available configuration items. Send to Controller is only visible when one or more Controllers are configured.
**Interval** By default, Interval will be set to 0 sec. as it is optional. When set > 0 it is the frequency used to read sensor values and send these to any Controllers configured for this device.
Values
^^^^^^
The measured values are available in variables, where the names are determined by the selected **Value 1..4** settings. A formula can be set to recalculate. The number of decimals can be set as desired, and defaults to 2.
Commands
~~~~~~~~
.. include:: P137_commands.repl
Extra values
~~~~~~~~~~~~
As this controller has more values available than can be set to the regular Values outputs, all values are also available from the Get Config feature.
.. include:: P137_values.repl
Change log
----------
.. versionchanged:: 2.0
|added| 2022-08-25 Initially added.