Files
ESPEasy/docs/source/Plugin/P092_ESR21.rst
T
uwekaditz bec007abb7 merged with release mega-20200305
merged with release mega-20200305
2020-03-09 19:59:56 +01:00

77 lines
2.1 KiB
ReStructuredText

.. include:: ../Plugin/_plugin_substitutions_p09x.repl
.. _P092_ESR21_page:
ESR21
=====
|P092_typename|
|P092_status|
Introduction
------------
The ESR21 unit is a simple solar control.
The ESR21 unit is a differential control that can be used in many ways
The DL bus runs at 12 volts.
The data frame consist of 30 bytes (excluding sync and CRC).
The data are transmitted @ 488Hz, therefore the transmission of one data set takes about 0.67 seconds.
.. image:: P092_ESR21.png
Wiring
------
.. image:: P092_12V_Wiring.png
Protocol
--------
.. image:: P092_ESR21_Protocol.png
Setup
-----
.. note:: A new device task must be created for each value to be read from the DL bus!
.. image:: P092_Setup.png
Task settings
~~~~~~~~~~~~~
* **Device**: Heating - DL-Bus (Technische Alternative)
* **Name**: Name of the task (example name **ValueN**, where N is a number).
* **Enable**: Should the task be enabled or not
Sensor
^^^^^^
* **1st GPIO**: DL bus input e.g. **GPIO 14 (D5)**
* **DL-Bus Type**: **ESR21**
.. note:: The settings for **1st GPIO** and **DL-Bus Type** must be the same for all used DL bus tasks!
Inputs
^^^^^^
.. note:: The description of the **Frame data** and the related **Frame bytes** can be found in the section **Protocol**!
.. csv-table::
:header: "Frame data", "Frame bytes", "Value", "Index", "Decimals"
:widths: 16, 8, 8, 5, 5
"Sensor1 ... Sensor3", "3 ... 8", "Sensor", "1 - 3", "1"
"Ext1 ... Ext6", "9 ... 20", "Ext. Sensor", "1 - 6", "1"
"Output byte", "21", "Digital Output", "", "0"
"Speed step", "22", "Speed step", "", "0"
"Analog output", "23", "Analog output", "", "1"
"Current power", "25,26", "Heat power [kW]", "", "1"
"Heat quantity", "27 ... 30", "Heat meter [MWh]", "", "4"
Data acquisition
^^^^^^^^^^^^^^^^
* **Send to controller** 1..3: Check which controller (if any) you want to publish to. All or no controller can be used.
* **Interval**: How often should the task publish its value (10..60 seconds is normal).
.. note:: Intervall not less than **10 seconds**! The reading of the DL bus happens twice per intervall.