event->BaseVarIndex is set only at a few places in the code, so adding checks there is enough to make sure all uses of event->BaseVarIndex are safe. Especially when computing a userVarIndex from event values (user input) the range should be checked before using it to access an element in the UserVar array.
175 lines
6.2 KiB
Arduino
175 lines
6.2 KiB
Arduino
#ifdef USES_DOMOTICZ
|
|
// HUM_STAT can be one of:
|
|
|
|
// 0=Normal
|
|
// 1=Comfortable
|
|
// 2=Dry
|
|
// 3=Wet
|
|
String humStatDomoticz(struct EventStruct *event, byte rel_index) {
|
|
userVarIndex_t userVarIndex = event->BaseVarIndex + rel_index;
|
|
if (validTaskVarIndex(rel_index) && validUserVarIndex(userVarIndex)) {
|
|
const int hum = UserVar[userVarIndex];
|
|
|
|
if (hum < 30) { return formatUserVarDomoticz(2); }
|
|
|
|
if (hum < 40) { return formatUserVarDomoticz(0); }
|
|
|
|
if (hum < 59) { return formatUserVarDomoticz(1); }
|
|
}
|
|
return formatUserVarDomoticz(3);
|
|
}
|
|
|
|
int mapRSSItoDomoticz() {
|
|
long rssi = WiFi.RSSI();
|
|
|
|
if (-50 < rssi) { return 10; }
|
|
|
|
if (rssi <= -98) { return 0; }
|
|
rssi = rssi + 97; // Range 0..47 => 1..9
|
|
return (rssi / 5) + 1;
|
|
}
|
|
|
|
int mapVccToDomoticz() {
|
|
#if FEATURE_ADC_VCC
|
|
|
|
// Voltage range from 2.6V .. 3.6V => 0..100%
|
|
if (vcc < 2.6) { return 0; }
|
|
return (vcc - 2.6) * 100;
|
|
#else // if FEATURE_ADC_VCC
|
|
return 255;
|
|
#endif // if FEATURE_ADC_VCC
|
|
}
|
|
|
|
// Format including trailing semi colon
|
|
String formatUserVarDomoticz(struct EventStruct *event, byte rel_index) {
|
|
String text = formatUserVarNoCheck(event, rel_index);
|
|
|
|
text += ';';
|
|
return text;
|
|
}
|
|
|
|
String formatUserVarDomoticz(int value) {
|
|
String text;
|
|
|
|
text += value;
|
|
text.trim();
|
|
text += ';';
|
|
return text;
|
|
}
|
|
|
|
String formatDomoticzSensorType(struct EventStruct *event) {
|
|
String values;
|
|
|
|
switch (event->sensorType)
|
|
{
|
|
case SENSOR_TYPE_SINGLE: // single value sensor, used for Dallas, BH1750, etc
|
|
values = formatUserVarDomoticz(event, 0);
|
|
break;
|
|
case SENSOR_TYPE_LONG: // single LONG value, stored in two floats (rfid tags)
|
|
values = (unsigned long)UserVar[event->BaseVarIndex] + ((unsigned long)UserVar[event->BaseVarIndex + 1] << 16);
|
|
break;
|
|
case SENSOR_TYPE_DUAL: // any sensor that uses two simple values
|
|
values = formatUserVarDomoticz(event, 0);
|
|
values += formatUserVarDomoticz(event, 1);
|
|
break;
|
|
case SENSOR_TYPE_TEMP_HUM:
|
|
|
|
// temp + hum + hum_stat, used for DHT11
|
|
// http://www.domoticz.com/wiki/Domoticz_API/JSON_URL%27s#Temperature.2Fhumidity
|
|
values = formatUserVarDomoticz(event, 0); // TEMP = Temperature
|
|
values += formatUserVarDomoticz(event, 1); // HUM = Humidity
|
|
values += humStatDomoticz(event, 1); // HUM_STAT = Humidity status
|
|
break;
|
|
case SENSOR_TYPE_TEMP_HUM_BARO:
|
|
|
|
// temp + hum + hum_stat + bar + bar_fore, used for BME280
|
|
// http://www.domoticz.com/wiki/Domoticz_API/JSON_URL%27s#Temperature.2Fhumidity.2Fbarometer
|
|
values = formatUserVarDomoticz(event, 0); // TEMP = Temperature
|
|
values += formatUserVarDomoticz(event, 1); // HUM = Humidity
|
|
values += humStatDomoticz(event, 1); // HUM_STAT = Humidity status
|
|
values += formatUserVarDomoticz(event, 2); // BAR = Barometric pressure
|
|
values += formatUserVarDomoticz(0); // BAR_FOR = Barometer forecast
|
|
break;
|
|
case SENSOR_TYPE_TEMP_BARO:
|
|
|
|
// temp + hum + hum_stat + bar + bar_fore, used for BMP085
|
|
// http://www.domoticz.com/wiki/Domoticz_API/JSON_URL%27s#Temperature.2Fbarometer
|
|
values = formatUserVarDomoticz(event, 0); // TEMP = Temperature
|
|
values += formatUserVarDomoticz(event, 1); // BAR = Barometric pressure
|
|
values += formatUserVarDomoticz(0); // BAR_FOR = Barometer forecast
|
|
values += formatUserVarDomoticz(0); // ALTITUDE= Not used at the moment, can be 0
|
|
break;
|
|
case SENSOR_TYPE_TEMP_EMPTY_BARO:
|
|
|
|
// temp + bar + bar_fore, used for BMP280
|
|
// http://www.domoticz.com/wiki/Domoticz_API/JSON_URL%27s#Temperature.2Fbarometer
|
|
values = formatUserVarDomoticz(event, 0); // TEMP = Temperature
|
|
values += formatUserVarDomoticz(event, 2); // BAR = Barometric pressure
|
|
values += formatUserVarDomoticz(0); // BAR_FOR = Barometer forecast
|
|
values += formatUserVarDomoticz(0); // ALTITUDE= Not used at the moment, can be 0
|
|
break;
|
|
case SENSOR_TYPE_TRIPLE:
|
|
values = formatUserVarDomoticz(event, 0);
|
|
values += formatUserVarDomoticz(event, 1);
|
|
values += formatUserVarDomoticz(event, 2);
|
|
break;
|
|
case SENSOR_TYPE_QUAD:
|
|
values = formatUserVarDomoticz(event, 0);
|
|
values += formatUserVarDomoticz(event, 1);
|
|
values += formatUserVarDomoticz(event, 2);
|
|
values += formatUserVarDomoticz(event, 3);
|
|
break;
|
|
case SENSOR_TYPE_WIND:
|
|
|
|
// WindDir in degrees; WindDir as text; Wind speed average ; Wind speed gust; 0
|
|
// http://www.domoticz.com/wiki/Domoticz_API/JSON_URL%27s#Wind
|
|
values = formatUserVarDomoticz(event, 0); // WB = Wind bearing (0-359)
|
|
values += getBearing(UserVar[event->BaseVarIndex]); // WD = Wind direction (S, SW, NNW, etc.)
|
|
values += ";"; // Needed after getBearing
|
|
// Domoticz expects the wind speed in (m/s * 10)
|
|
values += toString((UserVar[event->BaseVarIndex + 1] * 10), ExtraTaskSettings.TaskDeviceValueDecimals[1]);
|
|
values += ";"; // WS = 10 * Wind speed [m/s]
|
|
values += toString((UserVar[event->BaseVarIndex + 2] * 10), ExtraTaskSettings.TaskDeviceValueDecimals[2]);
|
|
values += ";"; // WG = 10 * Gust [m/s]
|
|
values += formatUserVarDomoticz(0); // Temperature
|
|
values += formatUserVarDomoticz(0); // Temperature Windchill
|
|
break;
|
|
case SENSOR_TYPE_SWITCH:
|
|
case SENSOR_TYPE_DIMMER:
|
|
|
|
// Too specific for HTTP/MQTT
|
|
break;
|
|
case SENSOR_TYPE_STRING:
|
|
values = event->String2;
|
|
break;
|
|
default:
|
|
{
|
|
String log = F("Domoticz Controller: Not yet implemented sensor type: ");
|
|
log += event->sensorType;
|
|
log += F(" idx: ");
|
|
log += event->idx;
|
|
addLog(LOG_LEVEL_ERROR, log);
|
|
break;
|
|
}
|
|
}
|
|
|
|
// Now strip trailing semi colon.
|
|
int index_last_char = values.length() - 1;
|
|
|
|
if ((index_last_char > 0) && (values.charAt(index_last_char) == ';')) {
|
|
values.setCharAt(index_last_char, ' ');
|
|
}
|
|
values.trim();
|
|
{
|
|
String log = F(" Domoticz: Sensortype: ");
|
|
log += event->sensorType;
|
|
log += F(" idx: ");
|
|
log += event->idx;
|
|
log += F(" values: ");
|
|
log += values;
|
|
addLog(LOG_LEVEL_INFO, log);
|
|
}
|
|
return values;
|
|
}
|
|
#endif // USES_DOMOTICZ
|