mirror of
https://github.com/letscontrolit/ESPEasy.git
synced 2026-09-15 11:05:08 +00:00
Merge branch 'mega' into feature/taskvalueset_by_name
This commit is contained in:
@@ -95,7 +95,7 @@ This is automatically done when hardware serial is chosen.
|
||||
A transistor circuit must be added when hardware serial is used. Despite the extra work, the hardware serial method is strongly recommended.
|
||||
|
||||
.. attention::
|
||||
Hardware serial receiver (RX) uses ESP8266's D8 "boot" configuration pin.
|
||||
Hardware serial transmit (TX) uses ESP8266's D8 "boot" configuration pin.
|
||||
A transistor buffer is required to isolate the ESP8266 from the Nextion's RX input circuity.
|
||||
Omitting the transistor may prevent the ESP8266 from booting correctly!
|
||||
|
||||
|
||||
@@ -41,14 +41,12 @@ The Shield has a TB6612FNG driver chip that can control two DC motors that draw
|
||||
Motor supply voltage can range from 2.5VDC to 15.0VDC.
|
||||
There is also a STM32F030 microcontroller onboard that handles the i2c communication for command processing.
|
||||
|
||||
Warning: Only one Motor Shield can be used on a ESPEasy device. This is a limitation of the ESPEasy plugin.
|
||||
|
||||
Supported Hardware
|
||||
------------------
|
||||
|
||||
There are two variations of the Motor Shield. Originally only the Wemos V1.0 Motor Shield was supported.
|
||||
This board requires modification (custom STM32F030 firmware and solder jumpers).
|
||||
But in Oct-2020 the ESPEasy plugin was updated to support the Lolin 2.0 Motor Shield.
|
||||
But on mega-20200929 and later releases the plugin has been updated to support the Lolin 2.0 Motor Shield.
|
||||
The Lolin Shield requires no modifications which greatly simplifies a new installation.
|
||||
|
||||
Hardware Installation
|
||||
|
||||
@@ -31,9 +31,6 @@ It has a TB6612FNG driver chip that can control two DC motors that draw 1.2A or
|
||||
Motor supply voltage can range from 2.5VDC to 15.0VDC.
|
||||
There is also a STM32F030 microcontroller onboard that handles the i2c communication for command processing.
|
||||
|
||||
Only one Motor Shield can be used on a ESPEasy device.
|
||||
This is a limitation of the ESPEasy plugin.
|
||||
|
||||
Hardware Installation
|
||||
---------------------
|
||||
The Shield is designed to plug directly onto a Wemos D1 mini (ESP8266).
|
||||
@@ -79,7 +76,7 @@ Motor Shield Testing
|
||||
--------------------
|
||||
|
||||
The I2C scan function (found on ESPEasy's *Tools* page) can be used to confirm the board is seen by the bus.
|
||||
If the scan does not find address 0x30 then check your wiring and the ESPEasy plugin's configuration.
|
||||
If the scan does not find address 0x30 then check your wiring.
|
||||
The image below shows a successful Motor Shield I2C Scan:
|
||||
|
||||
.. figure:: P079_i2c_scan1.png
|
||||
@@ -143,33 +140,33 @@ A pair of switches (requires two *Switch input - Switch* plugins) are used to li
|
||||
.. code-block:: none
|
||||
|
||||
// Events
|
||||
On DoorOpen Do
|
||||
LolinMotorShieldCMD 0 Backward 30
|
||||
EndOn
|
||||
on DoorOpen do
|
||||
LolinMotorShieldCMD,0,Backward,30
|
||||
endon
|
||||
|
||||
On DoorClose Do
|
||||
LolinMotorShieldCMD 0 Forward 30
|
||||
EndOn
|
||||
on DoorClose do
|
||||
LolinMotorShieldCMD,0,Forward,30
|
||||
endon
|
||||
|
||||
On DoorStop Do
|
||||
LolinMotorShieldCMD 0 Stop
|
||||
EndOn
|
||||
on DoorStop do
|
||||
LolinMotorShieldCMD,0,Stop
|
||||
endon
|
||||
|
||||
// Timer for all day open door at time if not open
|
||||
On Clock#Time=All,07:00 do
|
||||
If [Limit1#Switch]!=1
|
||||
Event,DoorOpen
|
||||
Else
|
||||
Event,DoorStop
|
||||
on Clock#Time=All,07:00 do
|
||||
if [Limit1#Switch]!=1
|
||||
event,DoorOpen
|
||||
else
|
||||
event,DoorStop
|
||||
endif
|
||||
endon
|
||||
|
||||
// Timer for all day close door at time if not closed
|
||||
On Clock#Time=All,22:00 do
|
||||
If [Limit2#Switch]!=1
|
||||
Event,DoorClose
|
||||
Else
|
||||
Event,DoorStop
|
||||
on Clock#Time=All,22:00 do
|
||||
if [Limit2#Switch]!=1
|
||||
event,DoorClose
|
||||
else
|
||||
event,DoorStop
|
||||
endif
|
||||
endon
|
||||
|
||||
|
||||
@@ -30,14 +30,12 @@ It has a TB6612FNG driver chip that can control two DC motors that draw 1.2A or
|
||||
Motor supply voltage can range from 2.5VDC to 15.0VDC.
|
||||
There is also a STM32F030 microcontroller onboard that handles the i2c communication for command processing.
|
||||
|
||||
Only one Motor Shield can be used on a ESPEasy device. This is a limitation of the ESPEasy plugin.
|
||||
|
||||
Firmware Upgrade
|
||||
----------------
|
||||
Piotr Bugalski has re-written the firmware for the Wemos V1.0 Motor Shield. It is published at https://github.com/pbugalski/wemos_motor_shield.
|
||||
Details to Piotr's firmware redesign can be found `Here <https://hackaday.io/project/18439-motor-shield-reprogramming>`_
|
||||
|
||||
The original firmware has reliability issues, such as hard lockup (hang) of the I2C bus.
|
||||
The factory installed firmware has reliability issues, such as hard lockup (hang) of the I2C bus.
|
||||
When this occurs all I2c communication is lost.
|
||||
A power cycle is required to restore operation!
|
||||
|
||||
@@ -159,7 +157,7 @@ Motor Shield Testing
|
||||
--------------------
|
||||
|
||||
The I2C scan function (found on ESPEasy's *Tools* page) can be used to confirm the board is seen by the bus.
|
||||
If the scan does not find address 0x30 then check your wiring and the ESPEasy plugin's configuration.
|
||||
If the scan does not find address 0x30 then recheck your wiring.
|
||||
The image below shows a successful Motor Shield I2C Scan:
|
||||
|
||||
.. image:: P079_i2c_scan1.png
|
||||
@@ -203,33 +201,33 @@ A pair of switches (requires two *Switch input - Switch* plugins) are used to li
|
||||
.. code-block:: none
|
||||
|
||||
// Events
|
||||
On DoorOpen Do
|
||||
WemosMotorShieldCMD 0 Backward 30
|
||||
EndOn
|
||||
on DoorOpen do
|
||||
WemosMotorShieldCMD,0,Backward,30
|
||||
endon
|
||||
|
||||
On DoorClose Do
|
||||
WemosMotorShieldCMD 0 Forward 30
|
||||
EndOn
|
||||
on DoorClose do
|
||||
WemosMotorShieldCMD,0,Forward,30
|
||||
endon
|
||||
|
||||
On DoorStop Do
|
||||
WemosMotorShieldCMD 0 Stop
|
||||
EndOn
|
||||
on DoorStop do
|
||||
WemosMotorShieldCMD,0,Stop
|
||||
endon
|
||||
|
||||
// Timer for all day open door at time if not open
|
||||
On Clock#Time=All,07:00 do
|
||||
If [Limit1#Switch]!=1
|
||||
Event,DoorOpen
|
||||
Else
|
||||
Event,DoorStop
|
||||
on Clock#Time=All,07:00 do
|
||||
if [Limit1#Switch]!=1
|
||||
event,DoorOpen
|
||||
else
|
||||
event,DoorStop
|
||||
endif
|
||||
endon
|
||||
|
||||
// Timer for all day close door at time if not closed
|
||||
On Clock#Time=All,22:00 do
|
||||
If [Limit2#Switch]!=1
|
||||
Event,DoorClose
|
||||
Else
|
||||
Event,DoorStop
|
||||
on Clock#Time=All,22:00 do
|
||||
if [Limit2#Switch]!=1
|
||||
event,DoorClose
|
||||
else
|
||||
event,DoorStop
|
||||
endif
|
||||
endon
|
||||
|
||||
|
||||
@@ -9,7 +9,7 @@
|
||||
|
||||
","
|
||||
| The *WemosMotorShieldCMD* and *LolinMotorShieldCMD* command keywords are interchangeable.
|
||||
| The *LolinMotorShieldCMD* command keyword is available with Oct-2020 or later mega releases.
|
||||
| The *LolinMotorShieldCMD* command keyword is available on mega-20200929 and later releases.
|
||||
| All commands are case insensitive.
|
||||
|
||||
"
|
||||
@@ -43,7 +43,7 @@
|
||||
|
||||
","
|
||||
|
||||
*Brake* and *Standby* actions are only available with Oct-2020 or later mega releases.
|
||||
*Brake* and *Standby* actions are available on mega-20200929 and later releases.
|
||||
|
||||
**HTTP Examples:**
|
||||
|
||||
|
||||
Reference in New Issue