.. csv-table::
|
|
:header: "Command Syntax", "Extra information"
|
|
:widths: 20, 30
|
|
|
|
"
|
|
``oledframedcmd,<sub>``
|
|
|
|
Sub:
|
|
|
|
* ``on`` will turn the display ON.
|
|
* ``off`` will turn the display OFF.
|
|
* ``low`` will dim the display to low.
|
|
* ``med`` will dim the display to medium.
|
|
* ``high`` will set the brightness to maximum.
|
|
|
|
","
|
|
OLED displays will age quite fast, so it is not adviced to run them continously at max brightness.
|
|
|
|
Some displays do not accept all brightness levels and some also make a quite high pitch coil whine noise when running on some brightness levels.
|
|
So different levels of brightness can also be of help on those displays.
|
|
|
|
This command is shared with :ref:`P036_page`, so when having both plugins enabled, the command has to be prefixed with the taskname and a periode, like ``[thermo].oledframedcmd...``
|
|
"
|
|
"
|
|
``thermo,setpoint,<temperature>``
|
|
","
|
|
Set the setpoint value, that the thermostat feature will try to maintain.
|
|
"
|
|
"
|
|
``thermo,down``
|
|
","
|
|
Change the setpoint value down by 0.5 degrees, simulating a keypress on the Down button. This enables an alternative way to control the setpoint.
|
|
|
|
If Manual mode is active, the timeout will be decreased by 5 minutes.
|
|
"
|
|
"
|
|
``thermo,up``
|
|
","
|
|
Change the setpoint value up by 0.5 degrees, simulating a keypress on the Up button. This enables an alternative way to control the setpoint.
|
|
|
|
If Manual mode is active, the timeout will be increased by 5 minutes.
|
|
"
|
|
"
|
|
``thermo,modebtn``
|
|
","
|
|
Change the mode to the next circular value in the 1, 2, 0 range, simulating a keypress on the Mode button. This enables an alternative way to control the thermostat mode.
|
|
|
|
When Manual mode is selected, the timeout is by default set to 5 minutes, and after the timeout it returns to automatic mode.
|
|
"
|
|
"
|
|
``thermo,heating,<state>``
|
|
|
|
State:
|
|
|
|
``1`` / ``on``: Turn on the heating
|
|
|
|
Any other value: Turn off the heating.
|
|
","
|
|
Set on the heating manually, either to ``1`` / ``on`` (on) or off (any other value).
|
|
"
|
|
"
|
|
``thermo,mode,<mode>[,<timeout>]``
|
|
|
|
Mode:
|
|
|
|
``0`` / ``x`` = Off
|
|
|
|
``1`` / ``a`` = Automatic, the default thermostat mode.
|
|
|
|
``2`` / ``m`` = Manual, turns heating on, with a <timeout> value in minutes, after which the Automatic mode is enabled again.
|
|
|
|
Timeout: A timeout for Manual mode in minutes. When no timeout is provided it will return to Automatic mode nearly immediately (~1 second).
|
|
","
|
|
Set the thermostat mode.
|
|
"
|