mirror of
https://github.com/silvervest/OpenFlops-W1D.git
synced 2026-10-26 22:11:39 +00:00
Add header for USB and speaker signals - Thanks Ray Bellis
This commit is contained in:
1 parent
4f15609ac8
commit
4bea36cc0a
5 files changed
+2856
-2535
No files matched your search
@@ -63,6 +63,25 @@ X Pin_4 4 200 -200 150 L 50 50 1 1 P
|
||||
ENDDRAW
|
||||
ENDDEF
|
||||
#
|
||||
# Connector_Generic_Conn_01x02
|
||||
#
|
||||
DEF Connector_Generic_Conn_01x02 J 0 40 Y N 1 F N
|
||||
F0 "J" 0 100 50 H V C CNN
|
||||
F1 "Connector_Generic_Conn_01x02" 0 -200 50 H V C CNN
|
||||
F2 "" 0 0 50 H I C CNN
|
||||
F3 "" 0 0 50 H I C CNN
|
||||
$FPLIST
|
||||
Connector*:*_1x??_*
|
||||
$ENDFPLIST
|
||||
DRAW
|
||||
S -50 -95 0 -105 1 1 6 N
|
||||
S -50 5 0 -5 1 1 6 N
|
||||
S -50 50 50 -150 1 1 10 f
|
||||
X Pin_1 1 -200 0 150 R 50 50 1 1 P
|
||||
X Pin_2 2 -200 -100 150 R 50 50 1 1 P
|
||||
ENDDRAW
|
||||
ENDDEF
|
||||
#
|
||||
# Connector_Generic_Conn_01x04
|
||||
#
|
||||
DEF Connector_Generic_Conn_01x04 J 0 40 Y N 1 F N
|
||||
|
||||
+2364
-2176
File diff suppressed because it is too large.
Load diff
+337
-306
@@ -1,14 +1,14 @@
|
||||
(export (version D)
|
||||
(design
|
||||
(source /home/sukko/Documents/kicad/OpenFlops/OpenFlops.sch)
|
||||
(date "dom 18 ago 2019 22:43:57 CEST")
|
||||
(date "dom 18 ago 2019 23:29:33 CEST")
|
||||
(tool "Eeschema 5.1.2")
|
||||
(sheet (number 1) (name /) (tstamps /)
|
||||
(title_block
|
||||
(title OpenFlops)
|
||||
(company SukkoPera)
|
||||
(rev 1git)
|
||||
(date 2019-08-14)
|
||||
(date 2019-08-18)
|
||||
(source OpenFlops.sch)
|
||||
(comment (number 1) (value "Based on schematics by H.M."))
|
||||
(comment (number 2) (value "Licensed under CERN OHL v.1.2"))
|
||||
@@ -533,7 +533,21 @@
|
||||
(datasheet ~)
|
||||
(libsource (lib Device) (part C) (description "Unpolarized capacitor"))
|
||||
(sheetpath (names /) (tstamps /))
|
||||
(tstamp 5D58F4BB)))
|
||||
(tstamp 5D58F4BB))
|
||||
(comp (ref P8)
|
||||
(value USB_HEADER)
|
||||
(footprint OpenFlops:PinHeader_1x04_P2.54mm_Vertical)
|
||||
(datasheet ~)
|
||||
(libsource (lib Connector_Generic) (part Conn_01x04) (description "Generic connector, single row, 01x04, script generated (kicad-library-utils/schlib/autogen/connector/)"))
|
||||
(sheetpath (names /) (tstamps /))
|
||||
(tstamp 5D653966))
|
||||
(comp (ref P9)
|
||||
(value EXTERNAL_SPEAKER)
|
||||
(footprint OpenFlops:PinHeader_1x02_P2.54mm_Vertical)
|
||||
(datasheet ~)
|
||||
(libsource (lib Connector_Generic) (part Conn_01x02) (description "Generic connector, single row, 01x02, script generated (kicad-library-utils/schlib/autogen/connector/)"))
|
||||
(sheetpath (names /) (tstamps /))
|
||||
(tstamp 5D86073A)))
|
||||
(libparts
|
||||
(libpart (lib 74xx) (part 74HCT04)
|
||||
(aliases
|
||||
@@ -589,6 +603,17 @@
|
||||
(pin (num 3) (name D+) (type passive))
|
||||
(pin (num 4) (name GND) (type power_in))
|
||||
(pin (num 5) (name Shield) (type passive))))
|
||||
(libpart (lib Connector_Generic) (part Conn_01x02)
|
||||
(description "Generic connector, single row, 01x02, script generated (kicad-library-utils/schlib/autogen/connector/)")
|
||||
(docs ~)
|
||||
(footprints
|
||||
(fp Connector*:*_1x??_*))
|
||||
(fields
|
||||
(field (name Reference) J)
|
||||
(field (name Value) Conn_01x02))
|
||||
(pins
|
||||
(pin (num 1) (name Pin_1) (type passive))
|
||||
(pin (num 2) (name Pin_2) (type passive))))
|
||||
(libpart (lib Connector_Generic) (part Conn_01x04)
|
||||
(description "Generic connector, single row, 01x04, script generated (kicad-library-utils/schlib/autogen/connector/)")
|
||||
(docs ~)
|
||||
@@ -954,375 +979,381 @@
|
||||
(library (logical w_transistor)
|
||||
(uri /home/sukko/Documents/kicad/lib/libs-walter/library/w_transistor.lib)))
|
||||
(nets
|
||||
(net (code 1) (name +5V)
|
||||
(node (ref PU2) (pin 1))
|
||||
(node (ref PU12) (pin 1))
|
||||
(node (ref PU10) (pin 1))
|
||||
(node (ref PU5) (pin 1))
|
||||
(node (ref PU8) (pin 1))
|
||||
(node (ref PU6) (pin 1))
|
||||
(node (ref R6) (pin 2))
|
||||
(node (ref PU3) (pin 1))
|
||||
(node (ref PU15) (pin 1))
|
||||
(node (ref PU1) (pin 1))
|
||||
(node (ref PU7) (pin 1))
|
||||
(node (ref PU9) (pin 1))
|
||||
(node (ref PU11) (pin 1))
|
||||
(node (ref PU13) (pin 1))
|
||||
(node (ref C1) (pin 1))
|
||||
(node (ref U1) (pin 14))
|
||||
(node (ref C20) (pin 1))
|
||||
(node (ref P3) (pin 1))
|
||||
(node (ref U4) (pin 3))
|
||||
(node (ref PU14) (pin 1))
|
||||
(node (ref C19) (pin 1))
|
||||
(node (ref P4) (pin 4))
|
||||
(node (ref PU4) (pin 1))
|
||||
(node (ref C23) (pin 1))
|
||||
(node (ref P2) (pin 1)))
|
||||
(net (code 2) (name +3V3)
|
||||
(node (ref P6) (pin 2))
|
||||
(node (ref C10) (pin 1))
|
||||
(node (ref R10) (pin 1))
|
||||
(node (ref P4) (pin 10))
|
||||
(node (ref P4) (pin 7))
|
||||
(node (ref U3) (pin 64))
|
||||
(node (ref U3) (pin 13))
|
||||
(net (code 1) (name +3V3)
|
||||
(node (ref P7) (pin 2))
|
||||
(node (ref U3) (pin 48))
|
||||
(node (ref R3) (pin 1))
|
||||
(node (ref R4) (pin 1))
|
||||
(node (ref R21) (pin 2))
|
||||
(node (ref R20) (pin 2))
|
||||
(node (ref U3) (pin 1))
|
||||
(node (ref U3) (pin 19))
|
||||
(node (ref U3) (pin 32))
|
||||
(node (ref C18) (pin 1))
|
||||
(node (ref C17) (pin 1))
|
||||
(node (ref U3) (pin 48))
|
||||
(node (ref U3) (pin 64))
|
||||
(node (ref U3) (pin 13))
|
||||
(node (ref P6) (pin 2))
|
||||
(node (ref R4) (pin 1))
|
||||
(node (ref R3) (pin 1))
|
||||
(node (ref R21) (pin 2))
|
||||
(node (ref C10) (pin 1))
|
||||
(node (ref P4) (pin 10))
|
||||
(node (ref P4) (pin 7))
|
||||
(node (ref U4) (pin 2))
|
||||
(node (ref R10) (pin 1))
|
||||
(node (ref C17) (pin 1))
|
||||
(node (ref C6) (pin 1))
|
||||
(node (ref C7) (pin 1))
|
||||
(node (ref C8) (pin 1))
|
||||
(node (ref C9) (pin 1))
|
||||
(node (ref R20) (pin 2)))
|
||||
(net (code 3) (name "Net-(P2-Pad4)")
|
||||
(node (ref P2) (pin 4)))
|
||||
(net (code 4) (name /spi_do)
|
||||
(node (ref U3) (pin 35)))
|
||||
(net (code 5) (name /spi_di)
|
||||
(node (ref U3) (pin 36)))
|
||||
(net (code 6) (name /spi_cs)
|
||||
(node (ref U3) (pin 33)))
|
||||
(net (code 7) (name /spi_clk)
|
||||
(node (ref U3) (pin 34)))
|
||||
(net (code 8) (name "Net-(RN2-Pad2)")
|
||||
(node (ref RN2) (pin 2))
|
||||
(node (ref U1) (pin 4)))
|
||||
(net (code 9) (name "Net-(LD1-Pad2)")
|
||||
(node (ref R20) (pin 1))
|
||||
(node (ref LD1) (pin 2)))
|
||||
(net (code 10) (name /~index_3v3)
|
||||
(node (ref U3) (pin 61))
|
||||
(node (ref U1) (pin 1)))
|
||||
(net (code 11) (name "Net-(Q2-Pad1)")
|
||||
(node (ref RN2) (pin 1))
|
||||
(node (ref Q2) (pin 1)))
|
||||
(net (code 12) (name /~index)
|
||||
(node (ref PU3) (pin 2))
|
||||
(node (ref Q1) (pin 3))
|
||||
(node (ref P1) (pin 8)))
|
||||
(net (code 13) (name /~trk0)
|
||||
(node (ref Q2) (pin 3))
|
||||
(node (ref P1) (pin 26))
|
||||
(node (ref PU9) (pin 2)))
|
||||
(net (code 14) (name "Net-(Q3-Pad1)")
|
||||
(node (ref RN3) (pin 1))
|
||||
(node (ref Q3) (pin 1)))
|
||||
(net (code 15) (name "Net-(RN3-Pad2)")
|
||||
(node (ref RN3) (pin 2))
|
||||
(node (ref U1) (pin 6)))
|
||||
(net (code 16) (name /~wprot)
|
||||
(node (ref PU10) (pin 2))
|
||||
(node (ref P1) (pin 28))
|
||||
(node (ref Q3) (pin 3)))
|
||||
(net (code 17) (name /~wprot_3v3)
|
||||
(node (ref U3) (pin 57))
|
||||
(node (ref U1) (pin 5)))
|
||||
(net (code 18) (name /~trk0_3v3)
|
||||
(node (ref U1) (pin 3))
|
||||
(node (ref U3) (pin 58)))
|
||||
(net (code 19) (name /~rdy_3v3)
|
||||
(node (ref U1) (pin 9))
|
||||
(node (ref U3) (pin 55)))
|
||||
(net (code 20) (name /~side)
|
||||
(node (ref P1) (pin 32))
|
||||
(node (ref PU12) (pin 2))
|
||||
(node (ref U3) (pin 56)))
|
||||
(net (code 21) (name /~wgate)
|
||||
(node (ref P1) (pin 24))
|
||||
(node (ref U3) (pin 62))
|
||||
(node (ref PU8) (pin 2)))
|
||||
(net (code 22) (name /~rdata_3v3)
|
||||
(node (ref U1) (pin 11))
|
||||
(node (ref U3) (pin 23)))
|
||||
(net (code 23) (name /~dskchg_3v3)
|
||||
(node (ref U1) (pin 13))
|
||||
(node (ref U3) (pin 59)))
|
||||
(net (code 24) (name "Net-(Q1-Pad1)")
|
||||
(node (ref RN1) (pin 1))
|
||||
(node (ref Q1) (pin 1)))
|
||||
(net (code 25) (name "Net-(RN1-Pad2)")
|
||||
(node (ref RN1) (pin 2))
|
||||
(node (ref U1) (pin 2)))
|
||||
(net (code 26) (name /~dskchg)
|
||||
(node (ref PU1) (pin 2))
|
||||
(node (ref Q6) (pin 3))
|
||||
(node (ref P1) (pin 2)))
|
||||
(net (code 27) (name "Net-(D1-Pad1)")
|
||||
(node (ref U1) (pin 10))
|
||||
(node (ref D1) (pin 1))
|
||||
(node (ref RN5) (pin 2)))
|
||||
(net (code 28) (name GND)
|
||||
(node (ref P3) (pin 5))
|
||||
(node (ref P3) (pin 4))
|
||||
(node (ref P1) (pin 29))
|
||||
(node (ref P1) (pin 7))
|
||||
(node (ref P1) (pin 5))
|
||||
(node (ref P1) (pin 33))
|
||||
(node (ref P1) (pin 31))
|
||||
(node (ref P1) (pin 3))
|
||||
(node (ref P1) (pin 27))
|
||||
(node (ref P1) (pin 23))
|
||||
(node (ref P1) (pin 21))
|
||||
(node (ref P1) (pin 19))
|
||||
(node (ref P1) (pin 17))
|
||||
(node (ref P1) (pin 15))
|
||||
(node (ref P1) (pin 13))
|
||||
(node (ref P1) (pin 1))
|
||||
(node (ref P1) (pin 9))
|
||||
(node (ref C3) (pin 2))
|
||||
(node (ref U3) (pin 3))
|
||||
(node (ref U3) (pin 2))
|
||||
(node (ref C5) (pin 2))
|
||||
(node (ref U3) (pin 53))
|
||||
(node (ref U3) (pin 4))
|
||||
(node (ref C4) (pin 2))
|
||||
(node (ref U3) (pin 63))
|
||||
(node (ref U3) (pin 47))
|
||||
(node (ref U3) (pin 31))
|
||||
(node (ref U3) (pin 18))
|
||||
(node (ref P5) (pin 2))
|
||||
(node (ref P5) (pin 4))
|
||||
(node (ref U3) (pin 12))
|
||||
(node (ref S3) (pin 1))
|
||||
(node (ref S4) (pin 1))
|
||||
(node (ref C7) (pin 2))
|
||||
(node (ref C18) (pin 1)))
|
||||
(net (code 2) (name GND)
|
||||
(node (ref C1) (pin 2))
|
||||
(node (ref H1) (pin 1))
|
||||
(node (ref Q1) (pin 2))
|
||||
(node (ref C17) (pin 2))
|
||||
(node (ref C6) (pin 2))
|
||||
(node (ref C8) (pin 2))
|
||||
(node (ref C9) (pin 2))
|
||||
(node (ref R13) (pin 2))
|
||||
(node (ref Q4) (pin 2))
|
||||
(node (ref Q5) (pin 2))
|
||||
(node (ref Q6) (pin 2))
|
||||
(node (ref Q3) (pin 2))
|
||||
(node (ref Q2) (pin 2))
|
||||
(node (ref Q7) (pin 2))
|
||||
(node (ref P6) (pin 1))
|
||||
(node (ref P3) (pin 5))
|
||||
(node (ref P7) (pin 1))
|
||||
(node (ref U1) (pin 7))
|
||||
(node (ref P1) (pin 11))
|
||||
(node (ref C20) (pin 2))
|
||||
(node (ref C10) (pin 2))
|
||||
(node (ref P4) (pin 2))
|
||||
(node (ref C19) (pin 2))
|
||||
(node (ref Q7) (pin 2))
|
||||
(node (ref P8) (pin 4))
|
||||
(node (ref S3) (pin 1))
|
||||
(node (ref P3) (pin 4))
|
||||
(node (ref H5) (pin 1))
|
||||
(node (ref H4) (pin 1))
|
||||
(node (ref H3) (pin 1))
|
||||
(node (ref H2) (pin 1))
|
||||
(node (ref P4) (pin 8))
|
||||
(node (ref P4) (pin 6))
|
||||
(node (ref P4) (pin 2))
|
||||
(node (ref S4) (pin 1))
|
||||
(node (ref C10) (pin 2))
|
||||
(node (ref P5) (pin 4))
|
||||
(node (ref U3) (pin 12))
|
||||
(node (ref U3) (pin 63))
|
||||
(node (ref U3) (pin 47))
|
||||
(node (ref U3) (pin 31))
|
||||
(node (ref U3) (pin 18))
|
||||
(node (ref U3) (pin 4))
|
||||
(node (ref U3) (pin 3))
|
||||
(node (ref U3) (pin 2))
|
||||
(node (ref U3) (pin 53))
|
||||
(node (ref P5) (pin 2))
|
||||
(node (ref P1) (pin 31))
|
||||
(node (ref C3) (pin 2))
|
||||
(node (ref C5) (pin 2))
|
||||
(node (ref P1) (pin 9))
|
||||
(node (ref P1) (pin 7))
|
||||
(node (ref P1) (pin 5))
|
||||
(node (ref P1) (pin 33))
|
||||
(node (ref P1) (pin 3))
|
||||
(node (ref P1) (pin 27))
|
||||
(node (ref P1) (pin 25))
|
||||
(node (ref P1) (pin 23))
|
||||
(node (ref P1) (pin 21))
|
||||
(node (ref P1) (pin 19))
|
||||
(node (ref P1) (pin 17))
|
||||
(node (ref P1) (pin 15))
|
||||
(node (ref P1) (pin 29))
|
||||
(node (ref C6) (pin 2))
|
||||
(node (ref C4) (pin 2))
|
||||
(node (ref P1) (pin 13))
|
||||
(node (ref P1) (pin 11))
|
||||
(node (ref P1) (pin 1))
|
||||
(node (ref P2) (pin 3))
|
||||
(node (ref P2) (pin 2))
|
||||
(node (ref U4) (pin 1))
|
||||
(node (ref C18) (pin 2))
|
||||
(node (ref C23) (pin 2))
|
||||
(node (ref C1) (pin 2))
|
||||
(node (ref P1) (pin 25))
|
||||
(node (ref P2) (pin 3))
|
||||
(node (ref P2) (pin 2)))
|
||||
(net (code 29) (name "Net-(Q4-Pad1)")
|
||||
(node (ref Q4) (pin 1))
|
||||
(node (ref RN4) (pin 1)))
|
||||
(net (code 30) (name "Net-(RN4-Pad2)")
|
||||
(node (ref RN4) (pin 2))
|
||||
(node (ref U1) (pin 8)))
|
||||
(net (code 31) (name /~rdy)
|
||||
(node (ref P1) (pin 34))
|
||||
(node (ref PU13) (pin 2))
|
||||
(node (ref Q4) (pin 3)))
|
||||
(net (code 32) (name "Net-(D1-Pad2)")
|
||||
(node (ref D1) (pin 2))
|
||||
(node (ref Q5) (pin 1))
|
||||
(node (ref RN5) (pin 1)))
|
||||
(net (code 33) (name /~rdata)
|
||||
(node (ref C19) (pin 2))
|
||||
(node (ref C17) (pin 2))
|
||||
(node (ref C7) (pin 2))
|
||||
(node (ref C8) (pin 2))
|
||||
(node (ref C9) (pin 2))
|
||||
(node (ref U1) (pin 7))
|
||||
(node (ref C20) (pin 2))
|
||||
(node (ref Q5) (pin 2))
|
||||
(node (ref Q3) (pin 2))
|
||||
(node (ref R13) (pin 2))
|
||||
(node (ref Q1) (pin 2))
|
||||
(node (ref Q2) (pin 2))
|
||||
(node (ref Q4) (pin 2))
|
||||
(node (ref Q6) (pin 2))
|
||||
(node (ref P6) (pin 1)))
|
||||
(net (code 3) (name "Net-(P2-Pad4)")
|
||||
(node (ref P2) (pin 4)))
|
||||
(net (code 4) (name +5V)
|
||||
(node (ref PU14) (pin 1))
|
||||
(node (ref P4) (pin 4))
|
||||
(node (ref PU13) (pin 1))
|
||||
(node (ref PU5) (pin 1))
|
||||
(node (ref PU7) (pin 1))
|
||||
(node (ref PU9) (pin 1))
|
||||
(node (ref PU11) (pin 1))
|
||||
(node (ref PU2) (pin 1))
|
||||
(node (ref PU4) (pin 1))
|
||||
(node (ref U1) (pin 14))
|
||||
(node (ref PU10) (pin 1))
|
||||
(node (ref C20) (pin 1))
|
||||
(node (ref C19) (pin 1))
|
||||
(node (ref PU12) (pin 1))
|
||||
(node (ref P8) (pin 1))
|
||||
(node (ref C23) (pin 1))
|
||||
(node (ref P3) (pin 1))
|
||||
(node (ref C1) (pin 1))
|
||||
(node (ref U4) (pin 3))
|
||||
(node (ref PU8) (pin 1))
|
||||
(node (ref PU6) (pin 1))
|
||||
(node (ref PU15) (pin 1))
|
||||
(node (ref PU3) (pin 1))
|
||||
(node (ref PU1) (pin 1))
|
||||
(node (ref R6) (pin 2))
|
||||
(node (ref P2) (pin 1)))
|
||||
(net (code 5) (name /spi_do)
|
||||
(node (ref U3) (pin 35)))
|
||||
(net (code 6) (name /spi_di)
|
||||
(node (ref U3) (pin 36)))
|
||||
(net (code 7) (name /spi_cs)
|
||||
(node (ref U3) (pin 33)))
|
||||
(net (code 8) (name /spi_clk)
|
||||
(node (ref U3) (pin 34)))
|
||||
(net (code 9) (name /~index)
|
||||
(node (ref PU3) (pin 2))
|
||||
(node (ref P1) (pin 8))
|
||||
(node (ref Q1) (pin 3)))
|
||||
(net (code 10) (name "Net-(Q2-Pad1)")
|
||||
(node (ref Q2) (pin 1))
|
||||
(node (ref RN2) (pin 1)))
|
||||
(net (code 11) (name /~trk0)
|
||||
(node (ref Q2) (pin 3))
|
||||
(node (ref PU9) (pin 2))
|
||||
(node (ref P1) (pin 26)))
|
||||
(net (code 12) (name /~dskchg)
|
||||
(node (ref Q6) (pin 3))
|
||||
(node (ref P1) (pin 2))
|
||||
(node (ref PU1) (pin 2)))
|
||||
(net (code 13) (name /~rdata)
|
||||
(node (ref P1) (pin 30))
|
||||
(node (ref PU11) (pin 2))
|
||||
(node (ref Q5) (pin 3)))
|
||||
(net (code 34) (name "Net-(Q6-Pad1)")
|
||||
(node (ref RN6) (pin 1))
|
||||
(node (ref Q6) (pin 1)))
|
||||
(net (code 35) (name "Net-(RN6-Pad2)")
|
||||
(node (ref RN6) (pin 2))
|
||||
(node (ref U1) (pin 12)))
|
||||
(net (code 36) (name /enc_clk)
|
||||
(node (ref U3) (pin 52))
|
||||
(node (ref P6) (pin 5)))
|
||||
(net (code 37) (name /enc_dt)
|
||||
(node (ref U3) (pin 51))
|
||||
(node (ref P6) (pin 4)))
|
||||
(net (code 38) (name /ja)
|
||||
(node (ref P6) (pin 3))
|
||||
(node (ref U3) (pin 37)))
|
||||
(net (code 39) (name "Net-(Q7-Pad1)")
|
||||
(node (ref Q7) (pin 1))
|
||||
(node (ref R5) (pin 1)))
|
||||
(net (code 40) (name "Net-(D2-Pad2)")
|
||||
(node (ref SPK1) (pin 2))
|
||||
(node (ref D2) (pin 2))
|
||||
(node (ref Q7) (pin 3)))
|
||||
(net (code 41) (name /jb)
|
||||
(node (ref R5) (pin 2))
|
||||
(node (ref U3) (pin 16)))
|
||||
(net (code 42) (name /swclk)
|
||||
(node (ref U3) (pin 49)))
|
||||
(net (code 43) (name "Net-(D2-Pad1)")
|
||||
(node (ref D2) (pin 1))
|
||||
(node (ref SPK1) (pin 1))
|
||||
(node (ref R6) (pin 1)))
|
||||
(net (code 44) (name /~sel0)
|
||||
(node (ref P5) (pin 9))
|
||||
(net (code 14) (name /~rdy)
|
||||
(node (ref PU13) (pin 2))
|
||||
(node (ref Q4) (pin 3))
|
||||
(node (ref P1) (pin 34)))
|
||||
(net (code 15) (name /~wprot)
|
||||
(node (ref Q3) (pin 3))
|
||||
(node (ref P1) (pin 28))
|
||||
(node (ref PU10) (pin 2)))
|
||||
(net (code 16) (name "Net-(RN2-Pad2)")
|
||||
(node (ref U1) (pin 4))
|
||||
(node (ref RN2) (pin 2)))
|
||||
(net (code 17) (name "Net-(Q3-Pad1)")
|
||||
(node (ref RN3) (pin 1))
|
||||
(node (ref Q3) (pin 1)))
|
||||
(net (code 18) (name "Net-(RN3-Pad2)")
|
||||
(node (ref RN3) (pin 2))
|
||||
(node (ref U1) (pin 6)))
|
||||
(net (code 19) (name /~trk0_3v3)
|
||||
(node (ref U1) (pin 3))
|
||||
(node (ref U3) (pin 58)))
|
||||
(net (code 20) (name /~wprot_3v3)
|
||||
(node (ref U1) (pin 5))
|
||||
(node (ref U3) (pin 57)))
|
||||
(net (code 21) (name "Net-(Q4-Pad1)")
|
||||
(node (ref RN4) (pin 1))
|
||||
(node (ref Q4) (pin 1)))
|
||||
(net (code 22) (name "Net-(RN4-Pad2)")
|
||||
(node (ref RN4) (pin 2))
|
||||
(node (ref U1) (pin 8)))
|
||||
(net (code 23) (name /~rdy_3v3)
|
||||
(node (ref U3) (pin 55))
|
||||
(node (ref U1) (pin 9)))
|
||||
(net (code 24) (name "Net-(D1-Pad2)")
|
||||
(node (ref RN5) (pin 1))
|
||||
(node (ref Q5) (pin 1))
|
||||
(node (ref D1) (pin 2)))
|
||||
(net (code 25) (name /~rdata_3v3)
|
||||
(node (ref U3) (pin 23))
|
||||
(node (ref U1) (pin 11)))
|
||||
(net (code 26) (name /~dskchg_3v3)
|
||||
(node (ref U3) (pin 59))
|
||||
(node (ref U1) (pin 13)))
|
||||
(net (code 27) (name "Net-(Q1-Pad1)")
|
||||
(node (ref Q1) (pin 1))
|
||||
(node (ref RN1) (pin 1)))
|
||||
(net (code 28) (name "Net-(RN1-Pad2)")
|
||||
(node (ref RN1) (pin 2))
|
||||
(node (ref U1) (pin 2)))
|
||||
(net (code 29) (name "Net-(LD1-Pad2)")
|
||||
(node (ref R20) (pin 1))
|
||||
(node (ref LD1) (pin 2)))
|
||||
(net (code 30) (name /~index_3v3)
|
||||
(node (ref U1) (pin 1))
|
||||
(node (ref U3) (pin 61)))
|
||||
(net (code 31) (name "Net-(D1-Pad1)")
|
||||
(node (ref RN5) (pin 2))
|
||||
(node (ref U1) (pin 10))
|
||||
(node (ref D1) (pin 1)))
|
||||
(net (code 32) (name "Net-(Q6-Pad1)")
|
||||
(node (ref Q6) (pin 1))
|
||||
(node (ref RN6) (pin 1)))
|
||||
(net (code 33) (name "Net-(RN6-Pad2)")
|
||||
(node (ref U1) (pin 12))
|
||||
(node (ref RN6) (pin 2)))
|
||||
(net (code 34) (name /~sel0)
|
||||
(node (ref P5) (pin 5))
|
||||
(node (ref P1) (pin 10))
|
||||
(node (ref P5) (pin 5)))
|
||||
(net (code 45) (name /~sel1)
|
||||
(node (ref P5) (pin 9)))
|
||||
(net (code 35) (name /~sel1)
|
||||
(node (ref P5) (pin 11))
|
||||
(node (ref P1) (pin 12))
|
||||
(node (ref P5) (pin 7))
|
||||
(node (ref P5) (pin 11)))
|
||||
(net (code 46) (name /~sely)
|
||||
(node (ref P5) (pin 7)))
|
||||
(net (code 36) (name /~sely)
|
||||
(node (ref LD2) (pin 1))
|
||||
(node (ref P5) (pin 8))
|
||||
(node (ref P5) (pin 6))
|
||||
(node (ref U3) (pin 17))
|
||||
(node (ref LD2) (pin 1))
|
||||
(node (ref PU15) (pin 2)))
|
||||
(net (code 47) (name "Net-(LD2-Pad2)")
|
||||
(net (code 37) (name "Net-(LD2-Pad2)")
|
||||
(node (ref LD2) (pin 2))
|
||||
(node (ref R21) (pin 1)))
|
||||
(net (code 48) (name /disp_dio)
|
||||
(node (ref U3) (pin 29))
|
||||
(node (ref R3) (pin 2))
|
||||
(node (ref P7) (pin 4)))
|
||||
(net (code 49) (name /disp_clk)
|
||||
(node (ref P7) (pin 3))
|
||||
(node (ref U3) (pin 30))
|
||||
(node (ref R4) (pin 2)))
|
||||
(net (code 50) (name /boot0)
|
||||
(net (code 38) (name /enc_dt)
|
||||
(node (ref P6) (pin 4))
|
||||
(node (ref U3) (pin 51)))
|
||||
(net (code 39) (name /enc_clk)
|
||||
(node (ref P6) (pin 5))
|
||||
(node (ref U3) (pin 52)))
|
||||
(net (code 40) (name /ja)
|
||||
(node (ref P6) (pin 3))
|
||||
(node (ref U3) (pin 37)))
|
||||
(net (code 41) (name /usb-r)
|
||||
(node (ref P8) (pin 2))
|
||||
(node (ref P3) (pin 2))
|
||||
(node (ref R2) (pin 1)))
|
||||
(net (code 42) (name /usb+r)
|
||||
(node (ref R1) (pin 1))
|
||||
(node (ref P8) (pin 3))
|
||||
(node (ref P3) (pin 3)))
|
||||
(net (code 43) (name /swclk)
|
||||
(node (ref U3) (pin 49)))
|
||||
(net (code 44) (name /tx)
|
||||
(node (ref P4) (pin 5))
|
||||
(node (ref U3) (pin 42)))
|
||||
(net (code 45) (name /rx)
|
||||
(node (ref U3) (pin 43))
|
||||
(node (ref P4) (pin 3)))
|
||||
(net (code 46) (name /nrst)
|
||||
(node (ref R10) (pin 2))
|
||||
(node (ref U3) (pin 7))
|
||||
(node (ref C4) (pin 1))
|
||||
(node (ref P4) (pin 1)))
|
||||
(net (code 47) (name /boot0)
|
||||
(node (ref U3) (pin 60))
|
||||
(node (ref P4) (pin 9))
|
||||
(node (ref R13) (pin 1)))
|
||||
(net (code 51) (name /tx)
|
||||
(node (ref P4) (pin 5))
|
||||
(node (ref U3) (pin 42)))
|
||||
(net (code 52) (name /rx)
|
||||
(node (ref P4) (pin 3))
|
||||
(node (ref U3) (pin 43)))
|
||||
(net (code 53) (name /nrst)
|
||||
(node (ref U3) (pin 7))
|
||||
(node (ref R10) (pin 2))
|
||||
(node (ref C4) (pin 1))
|
||||
(node (ref P4) (pin 1)))
|
||||
(net (code 48) (name /disp_dio)
|
||||
(node (ref R3) (pin 2))
|
||||
(node (ref P7) (pin 4))
|
||||
(node (ref U3) (pin 29)))
|
||||
(net (code 49) (name /disp_clk)
|
||||
(node (ref U3) (pin 30))
|
||||
(node (ref P7) (pin 3))
|
||||
(node (ref R4) (pin 2)))
|
||||
(net (code 50) (name /spk+)
|
||||
(node (ref SPK1) (pin 1))
|
||||
(node (ref D2) (pin 1))
|
||||
(node (ref P9) (pin 1))
|
||||
(node (ref R6) (pin 1)))
|
||||
(net (code 51) (name /spk-)
|
||||
(node (ref Q7) (pin 3))
|
||||
(node (ref D2) (pin 2))
|
||||
(node (ref P9) (pin 2))
|
||||
(node (ref SPK1) (pin 2)))
|
||||
(net (code 52) (name "Net-(Q7-Pad1)")
|
||||
(node (ref R5) (pin 1))
|
||||
(node (ref Q7) (pin 1)))
|
||||
(net (code 53) (name /jb)
|
||||
(node (ref R5) (pin 2))
|
||||
(node (ref U3) (pin 16)))
|
||||
(net (code 54) (name /~mtron)
|
||||
(node (ref PU14) (pin 2))
|
||||
(node (ref P1) (pin 16))
|
||||
(node (ref U3) (pin 50))
|
||||
(node (ref P5) (pin 13))
|
||||
(node (ref PU14) (pin 2)))
|
||||
(node (ref U3) (pin 50)))
|
||||
(net (code 55) (name /~sel2)
|
||||
(node (ref P1) (pin 14)))
|
||||
(net (code 56) (name /jc)
|
||||
(net (code 56) (name /~sel3)
|
||||
(node (ref P1) (pin 6)))
|
||||
(net (code 57) (name /jc)
|
||||
(node (ref U3) (pin 27))
|
||||
(node (ref P5) (pin 3)))
|
||||
(net (code 57) (name /~selx)
|
||||
(net (code 58) (name /~selx)
|
||||
(node (ref P5) (pin 12))
|
||||
(node (ref P5) (pin 10))
|
||||
(node (ref U3) (pin 14))
|
||||
(node (ref LD1) (pin 1))
|
||||
(node (ref P5) (pin 12))
|
||||
(node (ref P5) (pin 14))
|
||||
(node (ref PU4) (pin 2)))
|
||||
(net (code 58) (name "Net-(U3-Pad8)")
|
||||
(node (ref PU4) (pin 2))
|
||||
(node (ref LD1) (pin 1)))
|
||||
(net (code 59) (name /~wgate)
|
||||
(node (ref P1) (pin 24))
|
||||
(node (ref PU8) (pin 2))
|
||||
(node (ref U3) (pin 62)))
|
||||
(net (code 60) (name "Net-(U3-Pad8)")
|
||||
(node (ref U3) (pin 8)))
|
||||
(net (code 59) (name "Net-(U3-Pad9)")
|
||||
(net (code 61) (name "Net-(U3-Pad9)")
|
||||
(node (ref U3) (pin 9)))
|
||||
(net (code 60) (name "Net-(U3-Pad10)")
|
||||
(net (code 62) (name "Net-(U3-Pad10)")
|
||||
(node (ref U3) (pin 10)))
|
||||
(net (code 61) (name "Net-(U3-Pad11)")
|
||||
(net (code 63) (name "Net-(U3-Pad11)")
|
||||
(node (ref U3) (pin 11)))
|
||||
(net (code 62) (name "Net-(U3-Pad24)")
|
||||
(net (code 64) (name "Net-(U3-Pad24)")
|
||||
(node (ref U3) (pin 24)))
|
||||
(net (code 63) (name "Net-(U3-Pad25)")
|
||||
(net (code 65) (name "Net-(U3-Pad25)")
|
||||
(node (ref U3) (pin 25)))
|
||||
(net (code 64) (name "Net-(U3-Pad40)")
|
||||
(net (code 66) (name "Net-(S4-Pad2)")
|
||||
(node (ref S4) (pin 2))
|
||||
(node (ref U3) (pin 39)))
|
||||
(net (code 67) (name "Net-(U3-Pad40)")
|
||||
(node (ref U3) (pin 40)))
|
||||
(net (code 65) (name "Net-(U3-Pad54)")
|
||||
(net (code 68) (name "Net-(U3-Pad54)")
|
||||
(node (ref U3) (pin 54)))
|
||||
(net (code 66) (name /~wdata)
|
||||
(net (code 69) (name /~wdata)
|
||||
(node (ref U3) (pin 41))
|
||||
(node (ref PU7) (pin 2))
|
||||
(node (ref P1) (pin 22)))
|
||||
(net (code 67) (name /~step)
|
||||
(node (ref P1) (pin 22))
|
||||
(node (ref PU7) (pin 2)))
|
||||
(net (code 70) (name /~step)
|
||||
(node (ref PU6) (pin 2))
|
||||
(node (ref P1) (pin 20))
|
||||
(node (ref U3) (pin 15)))
|
||||
(net (code 68) (name "Net-(U3-Pad46)")
|
||||
(net (code 71) (name "Net-(U3-Pad46)")
|
||||
(node (ref U3) (pin 46)))
|
||||
(net (code 69) (name "Net-(U3-Pad20)")
|
||||
(net (code 72) (name "Net-(U3-Pad20)")
|
||||
(node (ref U3) (pin 20)))
|
||||
(net (code 70) (name "Net-(U3-Pad21)")
|
||||
(net (code 73) (name "Net-(U3-Pad21)")
|
||||
(node (ref U3) (pin 21)))
|
||||
(net (code 71) (name "Net-(U3-Pad22)")
|
||||
(net (code 74) (name "Net-(U3-Pad22)")
|
||||
(node (ref U3) (pin 22)))
|
||||
(net (code 72) (name /dir)
|
||||
(net (code 75) (name /dir)
|
||||
(node (ref U3) (pin 26))
|
||||
(node (ref P1) (pin 18))
|
||||
(node (ref PU5) (pin 2)))
|
||||
(net (code 73) (name "Net-(U3-Pad28)")
|
||||
(net (code 76) (name "Net-(U3-Pad28)")
|
||||
(node (ref U3) (pin 28)))
|
||||
(net (code 74) (name "Net-(C3-Pad1)")
|
||||
(node (ref Y1) (pin 1))
|
||||
(net (code 77) (name /~side)
|
||||
(node (ref U3) (pin 56))
|
||||
(node (ref PU12) (pin 2))
|
||||
(node (ref P1) (pin 32)))
|
||||
(net (code 78) (name /~inuse)
|
||||
(node (ref P5) (pin 1))
|
||||
(node (ref PU2) (pin 2))
|
||||
(node (ref P1) (pin 4)))
|
||||
(net (code 79) (name "Net-(C3-Pad1)")
|
||||
(node (ref C3) (pin 1))
|
||||
(node (ref U3) (pin 5)))
|
||||
(net (code 75) (name "Net-(C5-Pad1)")
|
||||
(node (ref Y1) (pin 2))
|
||||
(node (ref U3) (pin 5))
|
||||
(node (ref Y1) (pin 1)))
|
||||
(net (code 80) (name "Net-(C5-Pad1)")
|
||||
(node (ref U3) (pin 6))
|
||||
(node (ref C5) (pin 1))
|
||||
(node (ref U3) (pin 6)))
|
||||
(net (code 76) (name "Net-(S3-Pad2)")
|
||||
(node (ref S3) (pin 2))
|
||||
(node (ref U3) (pin 38)))
|
||||
(net (code 77) (name "Net-(S4-Pad2)")
|
||||
(node (ref S4) (pin 2))
|
||||
(node (ref U3) (pin 39)))
|
||||
(net (code 78) (name "Net-(P3-Pad2)")
|
||||
(node (ref P3) (pin 2))
|
||||
(node (ref R2) (pin 1)))
|
||||
(net (code 79) (name /usb+)
|
||||
(node (ref Y1) (pin 2)))
|
||||
(net (code 81) (name "Net-(S3-Pad2)")
|
||||
(node (ref U3) (pin 38))
|
||||
(node (ref S3) (pin 2)))
|
||||
(net (code 82) (name /usb+)
|
||||
(node (ref R1) (pin 2))
|
||||
(node (ref U3) (pin 45)))
|
||||
(net (code 80) (name /usb-)
|
||||
(net (code 83) (name /usb-)
|
||||
(node (ref R2) (pin 2))
|
||||
(node (ref U3) (pin 44)))
|
||||
(net (code 81) (name "Net-(P3-Pad3)")
|
||||
(node (ref P3) (pin 3))
|
||||
(node (ref R1) (pin 1)))
|
||||
(net (code 82) (name /~sel3)
|
||||
(node (ref P1) (pin 6)))
|
||||
(net (code 83) (name /~inuse)
|
||||
(node (ref P5) (pin 1))
|
||||
(node (ref P1) (pin 4))
|
||||
(node (ref PU2) (pin 2)))))
|
||||
(node (ref U3) (pin 44)))))
|
||||
+128
-52
@@ -6,7 +6,7 @@ $Descr A4 11693 8268
|
||||
encoding utf-8
|
||||
Sheet 1 1
|
||||
Title "OpenFlops"
|
||||
Date "2019-08-14"
|
||||
Date "2019-08-18"
|
||||
Rev "1git"
|
||||
Comp "SukkoPera"
|
||||
Comment1 "Based on schematics by H.M."
|
||||
@@ -952,36 +952,34 @@ Wire Wire Line
|
||||
$Comp
|
||||
L Device:R R1
|
||||
U 1 1 5D7861B9
|
||||
P 7480 1050
|
||||
F 0 "R1" V 7385 1050 50 0000 C CNN
|
||||
F 1 "22" V 7480 1050 50 0000 C CNN
|
||||
F 2 "Resistor_SMD:R_0805_2012Metric_Pad1.15x1.40mm_HandSolder" V 7410 1050 50 0001 C CNN
|
||||
F 3 "~" H 7480 1050 50 0001 C CNN
|
||||
1 7480 1050
|
||||
P 7345 1050
|
||||
F 0 "R1" V 7250 1050 50 0000 C CNN
|
||||
F 1 "22" V 7345 1050 50 0000 C CNN
|
||||
F 2 "Resistor_SMD:R_0805_2012Metric_Pad1.15x1.40mm_HandSolder" V 7275 1050 50 0001 C CNN
|
||||
F 3 "~" H 7345 1050 50 0001 C CNN
|
||||
1 7345 1050
|
||||
0 1 1 0
|
||||
$EndComp
|
||||
$Comp
|
||||
L Device:R R2
|
||||
U 1 1 5D786893
|
||||
P 7480 1150
|
||||
F 0 "R2" V 7575 1150 50 0000 C CNN
|
||||
F 1 "22" V 7480 1150 50 0000 C CNN
|
||||
F 2 "Resistor_SMD:R_0805_2012Metric_Pad1.15x1.40mm_HandSolder" V 7410 1150 50 0001 C CNN
|
||||
F 3 "~" H 7480 1150 50 0001 C CNN
|
||||
1 7480 1150
|
||||
P 7345 1150
|
||||
F 0 "R2" V 7440 1150 50 0000 C CNN
|
||||
F 1 "22" V 7345 1150 50 0000 C CNN
|
||||
F 2 "Resistor_SMD:R_0805_2012Metric_Pad1.15x1.40mm_HandSolder" V 7275 1150 50 0001 C CNN
|
||||
F 3 "~" H 7345 1150 50 0001 C CNN
|
||||
1 7345 1150
|
||||
0 1 1 0
|
||||
$EndComp
|
||||
Wire Wire Line
|
||||
7630 1050 7765 1050
|
||||
7495 1050 7765 1050
|
||||
Wire Wire Line
|
||||
7630 1150 7765 1150
|
||||
7195 1050 7010 1050
|
||||
Wire Wire Line
|
||||
7330 1050 7065 1050
|
||||
Wire Wire Line
|
||||
7330 1150 7065 1150
|
||||
Text Label 7065 1050 0 50 ~ 0
|
||||
7195 1150 7010 1150
|
||||
Text Label 7010 1050 0 50 ~ 0
|
||||
usb+
|
||||
Text Label 7065 1150 0 50 ~ 0
|
||||
Text Label 7010 1150 0 50 ~ 0
|
||||
usb-
|
||||
Wire Wire Line
|
||||
3255 2400 3820 2400
|
||||
@@ -1901,40 +1899,40 @@ Wire Wire Line
|
||||
$Comp
|
||||
L Device:CP1 C1
|
||||
U 1 1 5EE6C285
|
||||
P 6800 1130
|
||||
F 0 "C1" H 6685 1176 50 0000 R CNN
|
||||
F 1 "100u" H 6685 1085 50 0000 R CNN
|
||||
F 2 "Capacitor_THT:CP_Radial_D6.3mm_P2.50mm" H 6800 1130 50 0001 C CNN
|
||||
F 3 "~" H 6800 1130 50 0001 C CNN
|
||||
1 6800 1130
|
||||
P 4520 2195
|
||||
F 0 "C1" H 4405 2241 50 0000 R CNN
|
||||
F 1 "100u" H 4405 2150 50 0000 R CNN
|
||||
F 2 "Capacitor_THT:CP_Radial_D6.3mm_P2.50mm" H 4520 2195 50 0001 C CNN
|
||||
F 3 "~" H 4520 2195 50 0001 C CNN
|
||||
1 4520 2195
|
||||
1 0 0 -1
|
||||
$EndComp
|
||||
$Comp
|
||||
L power:+5V #PWR0141
|
||||
U 1 1 5EE997A6
|
||||
P 6800 915
|
||||
F 0 "#PWR0141" H 6800 765 50 0001 C CNN
|
||||
F 1 "+5V" H 6815 1088 50 0000 C CNN
|
||||
F 2 "" H 6800 915 50 0001 C CNN
|
||||
F 3 "" H 6800 915 50 0001 C CNN
|
||||
1 6800 915
|
||||
P 4520 1980
|
||||
F 0 "#PWR0141" H 4520 1830 50 0001 C CNN
|
||||
F 1 "+5V" H 4535 2153 50 0000 C CNN
|
||||
F 2 "" H 4520 1980 50 0001 C CNN
|
||||
F 3 "" H 4520 1980 50 0001 C CNN
|
||||
1 4520 1980
|
||||
1 0 0 -1
|
||||
$EndComp
|
||||
Wire Wire Line
|
||||
6800 915 6800 980
|
||||
4520 1980 4520 2045
|
||||
$Comp
|
||||
L power:GND #PWR0142
|
||||
U 1 1 5EEC2A25
|
||||
P 6800 1345
|
||||
F 0 "#PWR0142" H 6800 1095 50 0001 C CNN
|
||||
F 1 "GND" H 6805 1172 50 0000 C CNN
|
||||
F 2 "" H 6800 1345 50 0001 C CNN
|
||||
F 3 "" H 6800 1345 50 0001 C CNN
|
||||
1 6800 1345
|
||||
P 4520 2410
|
||||
F 0 "#PWR0142" H 4520 2160 50 0001 C CNN
|
||||
F 1 "GND" H 4525 2237 50 0000 C CNN
|
||||
F 2 "" H 4520 2410 50 0001 C CNN
|
||||
F 3 "" H 4520 2410 50 0001 C CNN
|
||||
1 4520 2410
|
||||
1 0 0 -1
|
||||
$EndComp
|
||||
Wire Wire Line
|
||||
6800 1280 6800 1345
|
||||
4520 2345 4520 2410
|
||||
Text Label 7505 3305 0 50 ~ 0
|
||||
~index
|
||||
Wire Wire Line
|
||||
@@ -2533,23 +2531,21 @@ $EndComp
|
||||
Wire Wire Line
|
||||
4905 4020 4905 4060
|
||||
Wire Wire Line
|
||||
4720 4095 4720 4060
|
||||
4650 4095 4650 4060
|
||||
Wire Wire Line
|
||||
4720 4060 4905 4060
|
||||
4650 4060 4905 4060
|
||||
Connection ~ 4905 4060
|
||||
Wire Wire Line
|
||||
4905 4060 4905 4185
|
||||
Wire Wire Line
|
||||
4720 4395 4720 4435
|
||||
$Comp
|
||||
L Device:D D2
|
||||
U 1 1 5E2F4A52
|
||||
P 4720 4245
|
||||
F 0 "D2" V 4674 4324 50 0000 L CNN
|
||||
F 1 "1N5819 (?)" V 4765 4324 50 0000 L CNN
|
||||
F 2 "Diode_SMD:D_SOD-323_HandSoldering" H 4720 4245 50 0001 C CNN
|
||||
F 3 "~" H 4720 4245 50 0001 C CNN
|
||||
1 4720 4245
|
||||
P 4650 4245
|
||||
F 0 "D2" V 4604 4324 50 0000 L CNN
|
||||
F 1 "1N5819 (?)" V 4695 4324 50 0000 L CNN
|
||||
F 2 "Diode_SMD:D_SOD-323_HandSoldering" H 4650 4245 50 0001 C CNN
|
||||
F 3 "~" H 4650 4245 50 0001 C CNN
|
||||
1 4650 4245
|
||||
0 -1 1 0
|
||||
$EndComp
|
||||
$Comp
|
||||
@@ -2565,8 +2561,6 @@ F 3 "https://www.fairchildsemi.com/datasheets/2N/2N3904.pdf" H 4805 4655 50 000
|
||||
$EndComp
|
||||
Wire Wire Line
|
||||
4905 4285 4905 4435
|
||||
Wire Wire Line
|
||||
4720 4435 4905 4435
|
||||
Connection ~ 4905 4435
|
||||
Wire Wire Line
|
||||
4905 4435 4905 4455
|
||||
@@ -2591,4 +2585,86 @@ Wire Wire Line
|
||||
6900 3735 6900 3575
|
||||
Connection ~ 6495 3115
|
||||
Connection ~ 6495 3735
|
||||
$Comp
|
||||
L Connector_Generic:Conn_01x04 P8
|
||||
U 1 1 5D653966
|
||||
P 6345 1035
|
||||
F 0 "P8" H 6263 1352 50 0000 C CNN
|
||||
F 1 "USB_HEADER" H 6263 1261 50 0000 C CNN
|
||||
F 2 "OpenFlops:PinHeader_1x04_P2.54mm_Vertical" H 6345 1035 50 0001 C CNN
|
||||
F 3 "~" H 6345 1035 50 0001 C CNN
|
||||
1 6345 1035
|
||||
-1 0 0 -1
|
||||
$EndComp
|
||||
Wire Wire Line
|
||||
6545 1035 6810 1035
|
||||
Wire Wire Line
|
||||
6545 1135 6810 1135
|
||||
Text Label 6810 1035 2 50 ~ 0
|
||||
usb-r
|
||||
Text Label 6810 1135 2 50 ~ 0
|
||||
usb+r
|
||||
$Comp
|
||||
L power:+5V #PWR0144
|
||||
U 1 1 5D74D3BF
|
||||
P 6810 870
|
||||
F 0 "#PWR0144" H 6810 720 50 0001 C CNN
|
||||
F 1 "+5V" H 6825 1043 50 0000 C CNN
|
||||
F 2 "" H 6810 870 50 0001 C CNN
|
||||
F 3 "" H 6810 870 50 0001 C CNN
|
||||
1 6810 870
|
||||
-1 0 0 -1
|
||||
$EndComp
|
||||
Wire Wire Line
|
||||
6810 870 6810 935
|
||||
Wire Wire Line
|
||||
6810 935 6545 935
|
||||
$Comp
|
||||
L power:GND #PWR0145
|
||||
U 1 1 5D780CD9
|
||||
P 6810 1270
|
||||
F 0 "#PWR0145" H 6810 1020 50 0001 C CNN
|
||||
F 1 "GND" H 6815 1097 50 0000 C CNN
|
||||
F 2 "" H 6810 1270 50 0001 C CNN
|
||||
F 3 "" H 6810 1270 50 0001 C CNN
|
||||
1 6810 1270
|
||||
1 0 0 -1
|
||||
$EndComp
|
||||
Wire Wire Line
|
||||
6545 1235 6810 1235
|
||||
Wire Wire Line
|
||||
6810 1235 6810 1270
|
||||
$Comp
|
||||
L Connector_Generic:Conn_01x02 P9
|
||||
U 1 1 5D86073A
|
||||
P 4235 3670
|
||||
F 0 "P9" H 4153 3887 50 0000 C CNN
|
||||
F 1 "EXTERNAL_SPEAKER" H 4153 3796 50 0000 C CNN
|
||||
F 2 "OpenFlops:PinHeader_1x02_P2.54mm_Vertical" H 4235 3670 50 0001 C CNN
|
||||
F 3 "~" H 4235 3670 50 0001 C CNN
|
||||
1 4235 3670
|
||||
-1 0 0 -1
|
||||
$EndComp
|
||||
Wire Wire Line
|
||||
4435 3670 4680 3670
|
||||
Wire Wire Line
|
||||
4435 3770 4680 3770
|
||||
Wire Wire Line
|
||||
4650 4435 4650 4395
|
||||
Wire Wire Line
|
||||
4650 4435 4905 4435
|
||||
Text Label 4650 4435 0 50 ~ 0
|
||||
spk-
|
||||
Text Label 4680 3770 2 50 ~ 0
|
||||
spk-
|
||||
Text Label 4650 4060 0 50 ~ 0
|
||||
spk+
|
||||
Text Label 4680 3670 2 50 ~ 0
|
||||
spk+
|
||||
Text Label 7495 1050 0 50 ~ 0
|
||||
usb+r
|
||||
Text Label 7500 1150 0 50 ~ 0
|
||||
usb-r
|
||||
Wire Wire Line
|
||||
7495 1150 7765 1150
|
||||
$EndSCHEMATC
|
||||
+8
-1
@@ -1,4 +1,4 @@
|
||||
18600615391927626
|
||||
18602181555635626
|
||||
Battery
|
||||
BatteryHolder_Bulgin_BX0036_1xC
|
||||
Bulgin Battery Holder, BX0036, Battery Type C (https://www.bulgin.com/products/pub/media/bulgin/data/Battery_holders.pdf)
|
||||
@@ -49763,6 +49763,13 @@ mounting hole 3.2mm m3
|
||||
1
|
||||
1
|
||||
OpenFlops
|
||||
PinHeader_1x02_P2.54mm_Vertical
|
||||
Through hole straight pin header, 1x02, 2.54mm pitch, single row
|
||||
Through hole pin header THT 1x02 2.54mm single row
|
||||
0
|
||||
2
|
||||
2
|
||||
OpenFlops
|
||||
PinHeader_1x04_P2.54mm_Vertical
|
||||
Through hole straight pin header, 1x04, 2.54mm pitch, single row
|
||||
Through hole pin header THT 1x04 2.54mm single row
|
||||
|
||||
Reference in new issue