MiEL HVAC: add a web config page for the Modbus RTU slave (#25018)
Configure the Modbus RTU slave from the web UI instead of the console, the same way MQTT is set up. - a "Modbus RTU" button on the Configuration menu, next to "MQTT", built only with USE_MIEL_HVAC_MODBUS_SLAVE on ESP32 - the page has an "Enable Modbus RTU" checkbox plus address, baudrate and serial config, laid out like the MQTT and Logging pages. Save runs the HVACModbus* commands, which apply live, and returns to the Configuration menu. No reboot. A wrapped note appears when the MB Rx/Tx GPIOs are unassigned, without widening the page. - a "Modbus" sticker on the main-page status line while the slave is running No core files touched. The console commands are unchanged.
This commit is contained in:
@@ -51,6 +51,9 @@
|
||||
* (RS485 DE/RE - omit for auto-direction transceivers)
|
||||
* Commands HVACModbus 0|1, HVACModbusAddress 1..247, HVACModbusBaudrate 1200..115200,
|
||||
* HVACModbusConfig 8N1|8E1|8O1|8N2|8E2|8O2 (persisted, applied live)
|
||||
* Web a "Modbus RTU" button on the Configuration menu opens a page for the enable
|
||||
* flag and the three parameters above (saved via the commands, applied live -
|
||||
* no reboot). A "Modbus" status sticker shows while the slave runs
|
||||
* Function 0x01/0x02 read coils / discrete inputs, 0x03/0x04 read holding / input
|
||||
* codes registers, 0x05/0x0F/0x06/0x10 write coils / registers; CRC-16 checked,
|
||||
* broadcast (address 0) accepted for writes
|
||||
@@ -4561,6 +4564,91 @@ miel_hvac_web_getarg(void)
|
||||
|
||||
#undef MIEL_HVAC_WEB_GETARG
|
||||
}
|
||||
|
||||
#if defined(USE_MIEL_HVAC_MODBUS_SLAVE) && defined(ESP32)
|
||||
/*
|
||||
* Modbus RTU slave configuration page, reached from a "Modbus RTU" button on
|
||||
* the Configuration menu (the same place as "MQTT"). The enable flag and the
|
||||
* three parameters are saved through the HVACModbus* console commands, which
|
||||
* apply live - no reboot. While the slave is running a "Modbus" sticker is
|
||||
* shown on the main-page status line.
|
||||
*/
|
||||
#define MIEL_HVAC_WEB_MB_PAGE "hvac_mb"
|
||||
|
||||
static const char miel_hvac_web_mb_form[] PROGMEM =
|
||||
"<p><label><input id='mbe' type='checkbox'%s><b>Enable Modbus RTU</b></label></p>"
|
||||
"<p><b>" D_ADDRESS "</b> (1)<br><input id='mba' placeholder='1' value='%d'></p>"
|
||||
"<p><b>Baudrate</b><br><select id='mbr'>%s</select></p>"
|
||||
"<p><b>Config</b><br><select id='mbc'>%s</select></p>";
|
||||
|
||||
static void
|
||||
miel_hvac_web_mb_config(void)
|
||||
{
|
||||
static const uint32_t bauds[] =
|
||||
{ 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 };
|
||||
static const char cfgs[][4] =
|
||||
{ "8N1", "8E1", "8O1", "8N2", "8E2", "8O2" };
|
||||
String opts_baud;
|
||||
String opts_cfg;
|
||||
String cur_cfg;
|
||||
uint32_t cur_baud;
|
||||
unsigned int i;
|
||||
|
||||
if (!HttpCheckPriviledgedAccess())
|
||||
return;
|
||||
|
||||
if (Webserver->hasArg(F("save")))
|
||||
{
|
||||
String cmnd = F(D_CMND_BACKLOG "0 ");
|
||||
cmnd += F(D_CMND_MIEL_HVAC_MODBUS " ");
|
||||
cmnd += Webserver->hasArg(F("mbe")) ? F("1") : F("0");
|
||||
cmnd += AddWebCommand(PSTR(D_CMND_MIEL_HVAC_MODBUS_ADDRESS),
|
||||
PSTR("mba"), PSTR("1"));
|
||||
cmnd += AddWebCommand(PSTR(D_CMND_MIEL_HVAC_MODBUS_BAUDRATE),
|
||||
PSTR("mbr"), PSTR("9600"));
|
||||
cmnd += AddWebCommand(PSTR(D_CMND_MIEL_HVAC_MODBUS_CONFIG),
|
||||
PSTR("mbc"), PSTR("8N1"));
|
||||
ExecuteWebCommand((char *)cmnd.c_str());
|
||||
HandleConfiguration(); /* applied live, back to the menu */
|
||||
return;
|
||||
}
|
||||
|
||||
miel_hvac_mb_settings_clamp();
|
||||
cur_baud = (uint32_t)Settings->miel_hvac_mb_baudrate * 300;
|
||||
cur_cfg = GetSerialConfig(Settings->miel_hvac_mb_sconfig);
|
||||
|
||||
for (i = 0; i < nitems(bauds); i++)
|
||||
{
|
||||
char o[32];
|
||||
snprintf_P(o, sizeof(o), PSTR("<option%s>%u</option>"),
|
||||
(bauds[i] == cur_baud) ? " selected" : "", bauds[i]);
|
||||
opts_baud += o;
|
||||
}
|
||||
for (i = 0; i < nitems(cfgs); i++)
|
||||
{
|
||||
char o[36];
|
||||
snprintf_P(o, sizeof(o), PSTR("<option%s>%s</option>"),
|
||||
cur_cfg.equals(cfgs[i]) ? " selected" : "", cfgs[i]);
|
||||
opts_cfg += o;
|
||||
}
|
||||
|
||||
WSContentStart_P(PSTR("Modbus RTU"));
|
||||
WSContentSendStyle();
|
||||
WSContentSend_P(HTTP_FIELDSET_LEGEND, PSTR("Modbus RTU"));
|
||||
WSContentSend_P(HTTP_FORM_GET_ACTION, PSTR(MIEL_HVAC_WEB_MB_PAGE));
|
||||
WSContentSend_P(miel_hvac_web_mb_form,
|
||||
Settings->sbflag1.miel_hvac_mb_enable ? PSTR(" checked") : PSTR(""),
|
||||
Settings->miel_hvac_mb_address,
|
||||
opts_baud.c_str(), opts_cfg.c_str());
|
||||
if (!PinUsed(GPIO_MIEL_HVAC_MB_RX) || !PinUsed(GPIO_MIEL_HVAC_MB_TX))
|
||||
WSContentSend_P(PSTR("<p style='width:320px;max-width:100%%'>"
|
||||
"⚠ The \"MiEl HVAC MB Rx\" and \"MiEl HVAC MB Tx\" GPIOs "
|
||||
"are not assigned, so the slave cannot start.</p>"));
|
||||
WSContentSend_P(HTTP_FORM_END);
|
||||
WSContentSpaceButton(BUTTON_CONFIGURATION);
|
||||
WSContentStop();
|
||||
}
|
||||
#endif /* USE_MIEL_HVAC_MODBUS_SLAVE && ESP32 */
|
||||
#endif /* USE_WEBSERVER */
|
||||
|
||||
/*
|
||||
@@ -4888,6 +4976,21 @@ bool Xdrv44(uint32_t function)
|
||||
case FUNC_WEB_GET_ARG:
|
||||
miel_hvac_web_getarg();
|
||||
break;
|
||||
#if defined(USE_MIEL_HVAC_MODBUS_SLAVE) && defined(ESP32)
|
||||
case FUNC_WEB_ADD_BUTTON:
|
||||
WSContentSend_P(HTTP_FORM_BUTTON, PSTR(MIEL_HVAC_WEB_MB_PAGE),
|
||||
PSTR("Modbus RTU"));
|
||||
break;
|
||||
case FUNC_WEB_ADD_HANDLER:
|
||||
WebServer_on(PSTR("/" MIEL_HVAC_WEB_MB_PAGE), miel_hvac_web_mb_config);
|
||||
break;
|
||||
#ifdef USE_WEB_STATUS_LINE
|
||||
case FUNC_WEB_STATUS_RIGHT:
|
||||
if (sc->sc_mb != nullptr)
|
||||
WSContentStatusSticker(PSTR("Modbus"));
|
||||
break;
|
||||
#endif
|
||||
#endif
|
||||
#endif
|
||||
case FUNC_AFTER_TELEPERIOD:
|
||||
if (sc->sc_settings_set)
|
||||
|
||||
Reference in New Issue