Noticed a small inconsistency of the default light WebColor palette not fully matching the light palette example in my_user_config.h and the docs WebUI page. The color for COLOR_BUTTON_OFF was a long time ago changed from dark blue #08405e to the better-working pale blue #a1d9f7 without this being reflected in the defaults used in the absence of another #define value.
Of course, this normally makes no difference as the standard my_user_config.h defines a full dark palette anyway, but still....
New post-build script pio-tools/timestamp-firmware.py copies firmware
artifacts to timestamped filenames when append_timestamp = 1 is set in
the [tasmota] section of platformio_override.ini. Default off; standard
builds unaffected.
The timestamp is extracted from the ELF symbol table via nm: named PROGMEM
symbols mdate_P and mtime_P in GetBuildDateAndTime() carry __DATE__ and
__TIME__ respectively. Reading them from the ELF guarantees the filename
timestamp matches exactly the one the firmware reports at boot. No -g flag required.
Artifacts written with timestamp suffix (e.g. tasmota-4M-2026-05-01T19-02-06):
.bin, .bin.gz, .factory.bin (ESP32) -> build_output/firmware/
.elf -> build_output/firmware/
.map.gz -> build_output/map/
support_rtc.ino: mtime_P introduced as a named PROGMEM variable so nm can
locate __TIME__ by symbol name on all platforms, including ESP32 where
PSTR() is a no-op. Flash impact: +4 B; all other memory unchanged.
* MIELHVAC New features and bug fixes
## Changelog
### Bug Fixes
**Memory leak in `miel_hvac_pre_init()`** — `goto del` jumped past the `free(sc)` label, leaking the allocated struct on serial init failure. Replaced with explicit `delete`/`free`/`return`.
**`remotetemp_clear` semantics inverted** — variable was `true` on boot causing a CLR frame to be sent before any sensor registered. Renamed to `remotetemp_active`, initialised `false`.
**`HVACSetPurify` used wrong map** — `airdirection_map` was passed instead of `purifier_map`.
**`0x08` Set Run State flags wrong byte order** — flags are little-endian on the wire (ref: muart-group/muart-group.github.io#17). Removed `htons()` from all `0x08` flag assignments.
**`widevane_isee` false positives** — values like `0x84`/`0x85`/`0x8c` (ISEE bit + position nibble) incorrectly reported `AirDirection:"even"`. Reverted to exact-match for `0x80`, `0x28`, `0xaa`.
---
### New Features
**`0x42` HVAC Options polling** — added `miel_hvac_data_hvac_options` struct and `MIEL_HVAC_REQUEST_HVAC_OPTIONS` request. The unit is polled for Purifier, NightMode and EconoCool state. Requires short request form (len=1). Results stored in `sc_hvac_options` and published in SENSOR and HVACSETTINGS when `cap_run_state=true`.
**Run State commands (`0x41 0x08`)** — new commands `HVACSetPurify`, `HVACSetNightMode`, `HVACSetEconoCool` and `HVACSetAirDirection` sent via `0x08` on units that report `cap_run_state=true`. Optimistic update to `sc_hvac_options` applied before confirmation.
**EconoCool** — `0x08` byte 14, flag `0x10`, COOL mode only. Command `HVACSetEconoCool on|off`.
**Base Capabilities (`0x5B 0xC9`)** — queried once after connecting. Parsed into `miel_hvac_capabilities`. Results published flat inside `MiElHVAC` as `*Supported` fields. Temperature ranges published as °C. Raw packet in `CapabilitiesHex`.
**Capabilities-aware command validation** — commands blocked when unit reports feature unavailable: modes (heat/dry/fan), temperature range from capabilities, fan speeds, run state commands return `NotSupported` or `ControlNotSupported`.
**`0x42` polling skip** — skipped on units with `cap_run_state=false`, eliminating recurring timeouts.
**`miel_hvac_append_settings_json()`** — shared helper replacing ~80 lines of duplicated JSON code between SENSOR and HVACSETTINGS topics.
---
### JSON Changes
- `Power` (W) and `Energy` (kWh) published inside `MiElHVAC` and also in a separate `ENERGY{}` object outside `MiElHVAC` for Home Assistant auto-discovery
- `Purifier`, `NightMode`, `EconoCool` shown in SENSOR and HVACSETTINGS when `cap_run_state=true`; otherwise omitted
- `AirDirection` always shows current state from `0x62 0x02` regardless of control support
- `*Supported` capability fields published flat inside `MiElHVAC`: `HeatSupported`, `DrySupported`, `FanSupported`, `VaneVSupported`, `SwingSupported`, `AutoFanSupported`, `OutdoorTempSupported`, `AirDirectionSupported`, `PurifierSupported`, `NightModeSupported`, `EconoCoolSupported`
---
### Tested on
MSZ-LN25VG2W — `cap_run_state=false`, temp ranges 16–31 °C cool/auto, 10–31 °C heat, 5 fan speeds.
* Extend AirDirection capability, added web ui energy sensor, cleanup
### AirDirection — respect i-See sensor presence
`AirDirection` now requires three conditions instead of just the vertical vane capability:
- `cap_vane_v` — unit has a vertical vane
- `sc_has_isee` — i-See sensor observed at runtime (widevane ever seen with bit `0x80`, or value `0x28`/`0xaa`)
- `cap_run_state` — unit supports `0x08` for control
Resulting behaviour:
| `cap_vane_v` | `sc_has_isee` | `cap_run_state` | `AirDirection` visible | `AirDirectionSupported` |
|:-:|:-:|:-:|:-:|:-:|
| ❌ | — | — | hidden | `not_supported` |
| ✅ | ❌ | — | hidden | `not_supported` |
| ✅ | ✅ | ❌ | shown | `control_not_supported` |
| ✅ | ✅ | ✅ | shown | `on` |
Units with vertical + horizontal vanes but no i-See sensor now correctly report `AirDirectionSupported:"not_supported"` and omit `AirDirection` from both `MiElHVAC` and `HVACSettings` JSON.
### Capability field renames
For naming consistency across the `*Supported` fields:
- `cap_heat` → `cap_mode_heat`, `HeatSupported` → `ModeHeatSupported`
- `cap_dry` → `cap_mode_dry`, `DrySupported` → `ModeDrySupported`
- `cap_fan_mode` → `cap_mode_fan`, `FanSupported` → `ModeFanSupported`
- `cap_auto_fan` → `cap_fan_auto`, `AutoFanSupported` → `FanAutoSupported`
- `OutdoorTempSupported` → `OutdoorTemperatureSupported`
- `TempCool` / `TempHeat` / `TempAuto` → `SetTemperatureCoolMinMax` / `SetTemperatureHeatMinMax` / `SetTemperatureAutoMinMax`
### Energy values
- `Power` (W) and `Energy` (kWh) published both inside `MiElHVAC` and in a standard Tasmota `ENERGY{}` sub-object (`Power`/`Total`) for Home Assistant auto-discovery.
- Added Web UI rows via `FUNC_WEB_SENSOR` showing instantaneous power (W) and cumulative total (kWh) on the Tasmota main page.
### Runtime i-See detection
New `sc_has_isee` flag in `miel_hvac_softc`, set in `miel_hvac_input_settings` on the first widevane value indicating i-See state. Once set, stays set for the session.
**Practical note:** after boot, the flag starts `false`. Units with i-See that has never been activated since Tasmota started will show `AirDirection` as hidden until i-See is first used (via IR remote or `HVACSetAirDirection`). Safe default — prevents showing misleading values on units without i-See.
* MiElHVAC Full support of AirDirection control
* MiELHVAC fix globals, VLA, duplicate JSON fields and float formatting
## Summary
- **Remove file-scope globals** (`temp_type`, `remotetemp_active`,
`remotetemp_auto_clear_time`, `remotetemp_last_call_time`,
`remotetemp_half`): moved into `miel_hvac_softc` as `sc_temp_type`
and `sc_remotetemp_*`. All references updated. Eliminates potential
conflict with other drivers sharing the same translation unit.
- **Fix VLA in `miel_hvac_send`**: `char hex_d[(len + 1) * 2]` replaced
with fixed-size `(MIEL_HVAC_DATABUFLEN + 1) * 2`. Variable-length
arrays on the stack are disallowed by `-Wvla` and unreliable on
embedded targets.
- **Make `temp_type` explicit**: helper functions `miel_hvac_deg2temp`,
`miel_hvac_temp2deg`, `miel_hvac_roomtemp2deg` now take `bool
temp_type` as a parameter. Detection of the extended encoding moved
from render functions to `miel_hvac_input_data()`, removing a hidden
side effect inside JSON serialisation code.
- **Remove duplicate JSON fields**: `Purifier`, `NightMode`, `EconoCool`
were emitted twice (from both the settings block and the options
block). Options block now only emits `OptionsHex`.
- **Fix `RemoteTemperatureSensorAutoClearTime` JSON type**: was
serialised as a string (`"10000"`), now a proper JSON number (`10000`).
- **Bool consistency**: assignments `= 1` / `= 0` on `bool` fields
replaced with `= true` / `= false`.
* MiEl HVAC: sync SENSOR, HVACSettings and discovery on state change
When settings (power, mode, temp, fan, vane, etc.) are confirmed by
the unit, publish both tele/+/HVACSettings and tele/+/SENSOR so the
two topics stay consistent. Also call TasRediscover() to refresh the
retained tasmota/discovery/+/sensors snapshot used by HA on reconnect.
Apply the same treatment to Options (Purifier, NightMode, EconoCool):
when they change, update both tele/+/SENSOR and tele/+/HVACSettings
in addition to refreshing the discovery snapshot.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
---------
Co-authored-by: Claude Sonnet 4.6 <noreply@anthropic.com>
This helps configuring input devices as they need frames of three bytes
length and need the command twice. Just calling DaliSend twice is not
enough for this due to the delay.