mirror of
https://github.com/athom-tech/esp32-configs.git
synced 2026-09-11 09:02:33 +00:00
add Child Lock
This commit is contained in:
@@ -25,7 +25,7 @@ Each file contains a `dashboard_import` URL in the form `github://athom-tech/esp
|
||||
| `athom-2ch-relay-board.yaml` | Athom 2CH Relay Board | `esp32dev` | Two-channel relay board with local buttons, RF receiver support, and status telemetry. |
|
||||
| `athom-4ch-relay-board.yaml` | Athom 4CH Relay Board | `esp32dev` | Four-channel relay board with local buttons, RF receiver support, and status telemetry. |
|
||||
| `athom-8ch-relay-board.yaml` | Athom 8CH Relay Board | `esp32dev` | Eight-channel relay board with local buttons, RF receiver support, and status telemetry. |
|
||||
| `athom-dual-smart-plug-v3.yaml` | Athom Dual Plug V3 | `esp32-c3-devkitm-1` | Dual smart plug with independent relay control, per-channel and aggregate power monitoring, persistent energy totals, and energy reset controls. |
|
||||
| `athom-dual-smart-plug-v3.yaml` | Athom Dual Plug V3 | `esp32-c3-devkitm-1` | Dual-channel smart plug with independent relay control and buttons, dual-channel energy metering. |
|
||||
| `athom-energy-monitor-x2.yaml` | Athom Energy Meter | `esp32-c3-devkitm-1` | Two-channel energy monitor using the local `bl0906` component. |
|
||||
| `athom-energy-monitor-x6.yaml` | Athom Energy Meter | `esp32-c3-devkitm-1` | Six-channel energy monitor using the local `bl0906` component. |
|
||||
| `athom-garage-door.yaml` | Athom Garage Door | `esp32-c3-devkitm-1` | Garage door opener with relay control, door state inputs, template cover, and status LED. |
|
||||
@@ -133,7 +133,7 @@ If OTA fails, confirm that:
|
||||
- OTA and web server support are enabled in the device configurations.
|
||||
- Common diagnostic entities include status, uptime, Wi-Fi signal, and restart/factory-reset style buttons.
|
||||
- Power-monitoring devices expose voltage, current, power, energy, total energy, and related calculated sensors where supported by the hardware.
|
||||
- The dual smart plug exposes per-channel measurements plus total current and total active power, persists per-channel and aggregate energy totals, and provides controls to reset those totals.
|
||||
- The dual smart plug performs dual-channel energy metering with the `bl0939` chip over UART, exposing per-channel voltage, current, active power, energy, and daily energy, plus total current, total active power, and total energy. It persists per-channel and aggregate energy totals across reboots and provides buttons to reset each total. A configurable current limit (16 A by default) trips the affected channel off for overcurrent protection, a `Power On State` selector sets the boot behaviour (always off, always on, or restore previous state), and each channel can be toggled with its physical button (a 4-second hold triggers factory reset).
|
||||
- Presence and LD2450-based devices expose target, zone, presence, illuminance, and radar control entities.
|
||||
- Devices are expected to be discovered by Home Assistant through the ESPHome integration after they are on the network.
|
||||
|
||||
|
||||
@@ -10,7 +10,7 @@ substitutions:
|
||||
# Project Name
|
||||
project_name: China Athom Technology.Athom Dual Plug V3
|
||||
# Projection version denotes the release version of the yaml file, allowing checking of deployed vs latest version
|
||||
project_version: v3.0.4
|
||||
project_version: v3.0.5
|
||||
# Restore the relay (GPO switch) upon reboot to state:
|
||||
relay1_restore_mode: RESTORE_DEFAULT_ON
|
||||
relay2_restore_mode: RESTORE_DEFAULT_ON
|
||||
@@ -244,11 +244,21 @@ binary_sensor:
|
||||
- ON for at most 1s
|
||||
- OFF for at least 0.2s
|
||||
then:
|
||||
- switch.toggle: relay1
|
||||
# Ignore short press when child lock is on, to stop kids toggling the socket
|
||||
- if:
|
||||
condition:
|
||||
switch.is_off: child_lock
|
||||
then:
|
||||
- switch.toggle: relay1
|
||||
- timing:
|
||||
- ON for at least 4s
|
||||
then:
|
||||
- button.press: Reset
|
||||
# Ignore long press when child lock is on, to prevent accidental factory reset
|
||||
- if:
|
||||
condition:
|
||||
switch.is_off: child_lock
|
||||
then:
|
||||
- button.press: Reset
|
||||
|
||||
- platform: gpio
|
||||
pin:
|
||||
@@ -263,11 +273,21 @@ binary_sensor:
|
||||
- ON for at most 1s
|
||||
- OFF for at least 0.2s
|
||||
then:
|
||||
- switch.toggle: relay2
|
||||
# Ignore short press when child lock is on, to stop kids toggling the socket
|
||||
- if:
|
||||
condition:
|
||||
switch.is_off: child_lock
|
||||
then:
|
||||
- switch.toggle: relay2
|
||||
- timing:
|
||||
- ON for at least 4s
|
||||
then:
|
||||
- button.press: Reset
|
||||
# Ignore long press when child lock is on, to prevent accidental factory reset
|
||||
- if:
|
||||
condition:
|
||||
switch.is_off: child_lock
|
||||
then:
|
||||
- button.press: Reset
|
||||
|
||||
sensor:
|
||||
- platform: uptime
|
||||
@@ -493,7 +513,16 @@ switch:
|
||||
id: relay2
|
||||
restore_mode: ${relay2_restore_mode}
|
||||
icon: mdi:${power_plug_type}
|
||||
|
||||
|
||||
# Child lock: when on, ignore both physical buttons' short/long press, but keep remote (HA/web) control working
|
||||
- platform: template
|
||||
name: "Child Lock"
|
||||
id: child_lock
|
||||
icon: mdi:lock
|
||||
optimistic: true
|
||||
restore_mode: RESTORE_DEFAULT_OFF # Keep last state after power loss/reboot, default off on first boot
|
||||
entity_category: config
|
||||
|
||||
light:
|
||||
- platform: status_led
|
||||
name: "Status LED"
|
||||
|
||||
Reference in New Issue